4 Software Description
4.4 Error Messages
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 45
4.3.2.4 SYSTEM INFORMATION menu
LANGUAGE Language selection German/English
HARDWARE VERSION Hardware function state (LDU-X)
VERSION Software version
4.4 Error Messages
In the event of an error, the amber LED shines on the right of the LDU-X display and the refill unit
LED will flash. The respective error message is shown on the display. The following list shows all
error messages, sorted according to their error numbers.
4.4.1 Overview of Error Messages
Error Displays Error message topic
101 LDU WAS NOT ACTIVE!
PLEASE CHECK MEDIUM!
See Messages About Monitoring Coating Intervals
102 REFILL UNIT
NOT ACTIVE
See Messages About the Refill Unit
103 CLEANING IN MIN5 See Messages About the Cleaning Cycle
104 FLUXLEVEL LOW!
CYCLES LEFT20
See Messages About the Level Sensor
105 CARTRIDGE EMPTY
TAPPET IS MOVING
See Messages About the Refill Unit
106 CARTRIDGE EMPTY See Messages About the Refill Unit
107 REFILL NOT OK See Messages About the Refill Unit
108 SET SERVICE KEY
TO SERVICE POSITION
See Messages About the Key Switch
109 SET SERVICE KEY
TO PRODUCTION MODE
See Messages About the Key Switch
201 FLUXLEVEL LOW! See Messages About the Level Sensor
202 LEVEL SENSOR
NOT READY
See Messages About the Level Sensor
203 REFILL
UNIT BLOCKED
See Messages About the Refill Unit
204 EMERGENCY SWITCH
IS LOCKED
See Messages About the Emergency Stop
205 MISSING DIP PLATE See Messages About the Dip Plate and Dip Tray
206 PLEASE CHECK PLATES
AND
DIP TRAY
See Messages About the Dip Plate and Dip Tray
301 PLEASE CLEAN LDU See Messages About the Cleaning Cycle
302 TANK IS MOVING See Messages About the Dip Plate and Dip Tray
4 Software Description
4.4 Error Messages
46 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.4.2 Messages About the Level Sensor
Error Displays Description
104 FLUXLEVEL LOW!
CYCLES LEFT20
The level sensor has determined that there is not
enough flux present. CYCLES LEFT shows how often
coating will still be performed before the LDU-X
switches over to "Not Ready".
201 FLUXLEVEL LOW! The remaining cycles have been performed.
The LDU-X is now in the state "Not Ready".
202 LEVEL SENSOR
NOT READY
The control measurement by the sensor was unsuc-
cessful.
The LDU-X is in the state "Not Ready".
4.4.3 Messages About the Refill Unit
Error Displays Description
102 REFILL UNIT
NOT ACTIVE
The refill unit has been switched off or is not present.
105 CARTRIDGE EMPTY
TAPPET IS MOVING
The cartridge is empty and the plunger is being moved
back.
Wait until the plunger has been moved back.
106 CARTRIDGE EMPTY The cartridge is empty and the plunger is in the starting
position.
107 REFILL NOT OK After 3x filling, there is still not enough flux in the tank.
Check the flux supply for air in the hose or cartridge, a
torn or folded hose.
203 REFILL
UNIT BLOCKED
The refill unit is blocked and the plunger can not be
moved. Check the flux supply for folded hose or ex-
cessive fluid viscosity.
4.4.4 Messages About Monitoring Coating Intervals
Error Displays Description
101 LDU WAS NOT ACTIVE!
PLEASE CHECK MEDIUM!
The time interval since the last coating is too long.
The LDU-X was switched off or was already in service
mode.
Check the flux. If necessary, clean the dip elements
and refill the flux.
4.4.5 Messages About the Cleaning Cycle
Error Displays Description
103 CLEANING IN MIN5 The LDU-X will remain in the "ready" state for the num-
ber of minutes shown.
301 PLEASE CLEAN LDU The LDU-X is now in the state "Not Ready".
4.4.6 Messages About the Dip Plate and Dip Tray
Error Displays Description
205 MISSING DIP PLATE Insert the dip plate.
206 PLEASE CHECK PLATES
AND
DIP TRAY
Press the ENTER button.
Insert the dip plate, park plate and dip tray.
302 TANK IS MOVING Wait until the coating movement has been completed.
4 Software Description
4.4 Error Messages
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 47
4.4.7 Messages About the Key Switch
Error Displays Description
108 SET SERVICE KEY
TO SERVICE POSITION
To perform the selected function, switch the key switch
to the "Service" position (vertical).
109 SET SERVICE KEY
TO PRODUCTION MODE
To perform the selected function, switch the key switch
to the "Production" position (horizontal).
4.4.8 Messages About the Emergency Stop
Error Displays Description
204 EMERGENCY SWITCH
IS LOCKED
The emergency stop has been enabled.
Release the emergency stop.