4 Software Description 4.3 Menu Description 44 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 4.3.2.3 SYSTEM PARAMETERS menu SYSTEM POSITIONS Sets the hold positions for the motors and motor parameters CHANGE…

4 Software Description
4.3 Menu Description
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 43
4.3.2.2 PRODUCT PARAMETERS menu
The production parameters can be set in this menu.
NOTICE
The values shown in this section are the defaults for the individual parameters.
REFILL UNIToff Switches the refill unit on and off
LEVEL SENSORoff Switches the level sensor on and off
REFILL COUNTEROn Switches the refill counter on and off
REFILL COUNTER5000 Starting value for the refill counter
MAX.PAUSEoff Switches the non-coating time check on/off
MAX.PAUSEMIN3 The maximum time in minutes during which coating may not be
performed
MAINTEN-
ANCEoff
Switches the cleaning interval check on and off
CLEANING IN MIN480 Cleaning interval duration in minutes
CLEAN WARNING5 Warning display before end of cleaning interval in minutes
SPEED250 Coating speed
CYCLES LEFT20 Number of cycles which will still be coated if a warning is issued.
This applies, for example, if the level sensor reports that the level
of flux is too low.
REFILL CYCLES3 Number of coating cycles after each flux refill
WARM UP30 Number of coating cycles during warm up
TANK VOLUME
middle
Required tank level to be monitored by the sensor
STARTWARNINGon Switches the command to check flux at start of LDU on and off
These settings are checked by the system and corrected where necessary. For example, the refill
unit does not function without the level sensor. If multiple options are enabled, these will be priorit-
ized in the order listed in the menu.

4 Software Description
4.3 Menu Description
44 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.3.2.3 SYSTEM PARAMETERS menu
SYSTEM POSITIONS Sets the hold positions for the motors and motor parameters
CHANGE PASSWORD Enables you to change the password
LOAD DEFAULT Loads the preset parameter values
RESET SYSTEM Resets the LDU-X to its original (delivery) state
System positions submenu
TEACH X-POSITIONS Save the current X position as baseline value
TEACH Y-POSITIONS Save the current Y position as baseline value
PARAMETER X-AXIS Set the X positions and motor parameters
PARAMETER Z-AXIS Set the Z positions and motor parameters
The following parameters from the above mentioned functions can be set:
ZERO POS X/Z zero position (park plate and dip plate at same height)
X-REVERS POS Front reverse position of squeegee
X-ADJ POS Control position for sensor
X-SPDUP POS If the coating speed is reduced, the speed will be accelerated
again from this point
VELOCITY Speed outside the coating area.
ACCELER X/Z acceleration
POS ERR X/Z permissible position error
CHANGE POS Position for tank change
Z-DIPPOS Height of dip plate for dipping
Z-MOT DEL Waiting time after motor movement in ms

4 Software Description
4.4 Error Messages
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 45
4.3.2.4 SYSTEM INFORMATION menu
LANGUAGE Language selection German/English
HARDWARE VERSION Hardware function state (LDU-X)
VERSION Software version
4.4 Error Messages
In the event of an error, the amber LED shines on the right of the LDU-X display and the refill unit
LED will flash. The respective error message is shown on the display. The following list shows all
error messages, sorted according to their error numbers.
4.4.1 Overview of Error Messages
Error Displays Error message topic
101 LDU WAS NOT ACTIVE!
PLEASE CHECK MEDIUM!
See Messages About Monitoring Coating Intervals
102 REFILL UNIT
NOT ACTIVE
See Messages About the Refill Unit
103 CLEANING IN MIN5 See Messages About the Cleaning Cycle
104 FLUXLEVEL LOW!
CYCLES LEFT20
See Messages About the Level Sensor
105 CARTRIDGE EMPTY
TAPPET IS MOVING
See Messages About the Refill Unit
106 CARTRIDGE EMPTY See Messages About the Refill Unit
107 REFILL NOT OK See Messages About the Refill Unit
108 SET SERVICE KEY
TO SERVICE POSITION
See Messages About the Key Switch
109 SET SERVICE KEY
TO PRODUCTION MODE
See Messages About the Key Switch
201 FLUXLEVEL LOW! See Messages About the Level Sensor
202 LEVEL SENSOR
NOT READY
See Messages About the Level Sensor
203 REFILL
UNIT BLOCKED
See Messages About the Refill Unit
204 EMERGENCY SWITCH
IS LOCKED
See Messages About the Emergency Stop
205 MISSING DIP PLATE See Messages About the Dip Plate and Dip Tray
206 PLEASE CHECK PLATES
AND
DIP TRAY
See Messages About the Dip Plate and Dip Tray
301 PLEASE CLEAN LDU See Messages About the Cleaning Cycle
302 TANK IS MOVING See Messages About the Dip Plate and Dip Tray