7 Options 7.2 Refill Unit Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 77 ► Lift the LDU base unit to one side. ► Connect the diode cable to the terminal strip. ● Red to position K12 ● Black to position K13…

7 Options
7.2 Refill Unit
76 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Push the lower cover plate onto the LDU-
X.
Screwing the lower cover plate into place:
► Fasten the 5 screws marked in the dia-
gram.
► Turn the LDU-X onto its other side.
► Fasten the sixth screw.
► Run the cable behind the plate.
► Screw the plate to the refill unit.
► Stand the LDU-X upright again.
► Loosen the LDU-X base unit.

7 Options
7.2 Refill Unit
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 77
► Lift the LDU base unit to one side.
► Connect the diode cable to the terminal
strip.
●
Red to position K12
●
Black to position K13
NOTICE!
Observe the safety instructions in the ESD
guidelines.
.
●
Press the terminal in.
●
Plug-in the cable.
●
Let the terminal go.
► Lift the LDU-X base unit to the other side.
► Press the connector of the flat ribbon cable
from above, onto the marked free socket.
CAUTION!
Make sure that the connector has been
completely pressed into place.
.

7 Options
7.2 Refill Unit
78 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
► Lift the LDU-X base unit back into its
straight position again.
CAUTION!
Make sure that the flat ribbon cable is not
trapped.
.
► Fix the LDU base unit into place.
► Fix the hose attachment holder into place
(2 screws).
► Fix the cover plate into place (3 screws).
► If the plate does not fit, you will need to
slightly loosen the two screws fastening
the refill unit, adjust the position of the refill
unit accordingly and then retighten the
screws.