00196749-02_UM_LDU-X_EN.pdf - 第62页
6 Maintenance 6.2 Cleaning 62 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 CAUTION Proper disposal The flux and cleaning agents used may contain substances which are hazardous to the en- vironment. Read thr…

6 Maintenance
6.2 Cleaning
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 61
6.2.1 Removing the Parts to be Cleaned
► Finish the production run at the SIPLACE placement machines.
► Leave the placement machine switched on.
► Open the protective cover over the LDU-X.
► Get a suitable cleaning tub ready.
► Set the key switch on the LDU‑X to the position SERVICE.
The service menu will be shown on the LDU-X display.
► Select SERVICE FUNCTIONSfrom the menu.
► Press the ENTER button.
The individual service functions will be shown on the LDU-X display.
► Select CLEANING from the menu.
► Press the ENTER button.
The following section shows the messages which appear on the LDU-X display, explaining the or-
der in which the individual dip components are to be removed. For a detailed and illustrated de-
scription, refer to chapter 4.3.2.1.2.3 "CLEANING function" [}31].
► Clean the removed parts as described below. Leave the LDU‑X switched on while you are do-
ing this.
6.2.2 Cleaning the dip components
Dismantled parts in cleaning tank
Rough cleaning
► Roughly pre-clean all parts. Remove any excess flux. Use a wooden or plastic spatula or
scraper and cleansing tissues.
CAUTION
Do not scratch the parts.
The parts to be cleaned are precision machined and sensitive.
► Do not use any spatulas or scrapers made of metal or other sharp-edged objects.
Fine cleaning
► Place the parts in a tub.
► Clean the parts with a brush and suitable cleaning agent.
► Take the parts out of the tub.
► Dry the parts with cleansing tissues.

6 Maintenance
6.2 Cleaning
62 Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
CAUTION
Proper disposal
The flux and cleaning agents used may contain substances which are hazardous to the en-
vironment. Read through the relevant safety data sheet and pay particular attention to the
instructions for environmental protection (ecology) and disposal.
► Dispose of used cleansing tissues in the containers provided.
6.2.3 Refit the cleaned parts
► Go to the SERVICE FUNCTIONS menu and select FITTING SYSTEM.
► Press the ENTER button.
The following section shows the messages which appear on the LDU-X display, explaining the or-
der in which the individual dip components are to be fitted again. For a detailed and illustrated de-
scription, refer to chapter 4.3.2.1.2.4 "FITTING SYSTEM function" [}36].
If you want to begin or continue production, after the dip component cleaning cycle, insert the flux
tank and fill it immediately with flux.
CAUTION
Always use flux when operating the LDU-X.
If you operate the LDU-X without flux, there is a risk that the flux tank and plates may
scrape against one another. The flux acts as lubrication for these parts.
► Always use flux when operating the LDU-X.

7 Options
7.1 Level sensor
Operating Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 63
7 Options
7.1 Level sensor
The level sensor is responsible for monitoring the amount of flux in the flux tank. During the produc-
tion process, the level of flux will fall. If the amount of flux no longer completely fills the cavity in the
dip plate, this means that the components can no longer be coated with flux to the quality required.
7.1.1 Retrofitting the level sensor
Prerequisite
A level sensor can be retrofitted in the LDU-X from function state 2 (FS2) onwards.
The FS2 can be set by the Service team.
Equipment required
●
Standard tools
●
LDU flux level sensor [00117071-xx]
7.1.1.1 Opening the LDU-X
► Remove the top cover.
► Remove the dip plate.