Performing the measurement
Measurement 1
► Hold the measuring device with your thumb and forefinger on its guide roller.
► (1) Place the point which is opposite the zero value onto the flux surface and press down to
the base of the cavity.
► (2) und (3) Apply slight pressure and roll to the zero value.
► Lift the measuring device upwards.
Control measurement
► Position the device as in measurement 1.
► Roll in the opposite direction as far as the zero value.
► Read the flux layer thickness from the scale at the coating point (2) on the middle roller.
► Compare the measurement with that for the opposite side.
► Calculate the mean value of both results.
8.14 Testing New Flux Types
If you use a new flux, proceed as follows during the test phase.
► Calculate the relevant cavity for the product.
► Place the dip plate in the LDU-X.
► Fill in the flux. The flux surface should be between the two marks on the inside of the flux
tank.
► Set the application speed as very slow.
► Increase the application speed in steps.
► While doing this, observe the flux surface.
► Reduce the application speed again, if waves, dips or irregularities are formed on the surface.
► Select a long dwell time. This can be reduced later to achieve higher cycle times.
► Positioning upwards with slow start. This ensures that the component is not lost in the flux.