00198377-01_SM_JTF-ML2_en.pdf - 第126页

5 Electrics 5.3 Replacing the HMI LED Cable 126 Service Manual SIPLACE JTF-ML2 08/2017 ► Push the Cable, HMI LED assembly [03146655- xx] through the hole to the outside of the tower. Installation ► Follow the removal ins…

100%1 / 150
5 Electrics
5.3 Replacing the HMI LED Cable
Service Manual SIPLACE JTF-ML2 08/2017 125
5.3 Replacing the HMI LED Cable
Parts, Equipment and Tools
Standard tools
Cable, HMI LED assembly [03146655-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the Tower from the machine (see 2.1.2 "Removing Tower from Machine" [}21]).
Remove the top cover (see 2.1.3 "Removing Tower Top Cover" [}25]).
Disconnect the plug X1.H1 (2) of the Cable, HMI
LED assembly [03146655-xx] (1).
5 Electrics
5.3 Replacing the HMI LED Cable
126 Service Manual SIPLACE JTF-ML2 08/2017
Push the Cable, HMI LED assembly [03146655-
xx] through the hole to the outside of the tower.
Installation
Follow the removal instructions in reverse order for installation.
5 Electrics
5.4 Replacing the PCBA RFID Reader Board
Service Manual SIPLACE JTF-ML2 08/2017 127
5.4 Replacing the PCBA RFID Reader Board
Parts, Equipment and Tools
Standard tools
PCBA RFID Reader board [03146441-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the tower from the machine (see 2.1.2 "Removing Tower from Machine" [}21]).
Remove the top cover (see 2.1.3 "Removing Tower Top Cover" [}25]).
Remove the side cover (see 2.1.4 "Removing Side Cover" [}27]).
Carefully disconnect the cable (1) from X23 on
the PCBA, JFT-ML2 control board 03125534-xx].
Remove the six screws DIN EN ISO 7380-M3 x
6-A2-70 [03045194-xx] (1) on the right side.
Slide the Cable cover plate [03147170-xx] to the
right to remove it.