00198377-01_SM_JTF-ML2_en.pdf - 第137页

5 Electrics 5.10 Replacing the Door Safety Switch Service Manual SIPLACE JTF-ML2 08/2017 137 5.10 Replacing the Door Safety Switch Parts, Equipment and Tools ● Standard tools ● Door safety switch [03158838-xx] – Transpon…

100%1 / 150
5 Electrics
5.9 Replacing the PCBA Conveyor Drive Board
136 Service Manual SIPLACE JTF-ML2 08/2017
Remove the six screws DIN EN ISO 7380-M3 x
5-A2-70 [03045193-xx] (1).
Remove the PCBA, conveyor drive board
[03128812-xx].
Installation
Follow the removal instructions in reverse order for installation.
NOTICE
Crushing of cables
When assembling, test the position by plugging and unplugging it into the tower. The cables
should not be to tight to fit the board back in.
The distance between the PCBA Conveyor Drive
Board and the Conveyor has to be 7.7 +/- 0.1mm.
5 Electrics
5.10 Replacing the Door Safety Switch
Service Manual SIPLACE JTF-ML2 08/2017 137
5.10 Replacing the Door Safety Switch
Parts, Equipment and Tools
Standard tools
Door safety switch [03158838-xx]
Transponder safety switch STR1 [03143849-xx]
Transponder safety switch STR1 actuator [03154807-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the top cover (see 2.1.3 "Removing Tower Top Cover" [}25]).
Remove the Transponder safety switch STR1 [03143849-xx] (See 3.7 "Replacing the Door In-
sert Lock" [}49]).
Transponder safety switch STR1 [03143849-xx]
Remove the screw ISO 4762 - M 3 x 20-A2-70
[03042547-xx] (1)
Remove the Transponder safety switch STR1 actu-
ator [03154807-xx] (2).
Transponder safety switch STR1 actuator [03154807-xx]
Installation
Follow the removal instructions in reverse order for installation.
5 Electrics
5.11 Replacing Slot Sensor w/ Connector
138 Service Manual SIPLACE JTF-ML2 08/2017
5.11 Replacing Slot Sensor w/ Connector
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the SIPLACE JTF-ML2 from the machine (see Removing SIPLACE JTF-ML2 from
Machine).
Remove the top cover (see 2.1.3 "Removing Tower Top Cover" [}25]).
Remove the side cover (see 2.1.4 "Removing Side Cover" [}27]).
Place the JFT-ML2 on a stable surface like a work bench while working on it.
Remove all cables from the PCBA, JFT-ML2 con-
trol board [03125534-xx].
1. X22; X8; X7; X6; X5
2. X16; X15
3. X23
4. X18; X19; X17
5. X4
Remove the four screws ISO 4762 - M 3 x 6-
A2-70 [03042541-xx] (1).
Remove the Plate f. PCBA Support [03129139-
xx] (2).