00198377-01_SM_JTF-ML2_en.pdf - 第133页

5 Electrics 5.8 Replacing the Reflective Sensor Cable Service Manual SIPLACE JTF-ML2 08/2017 133 ► Remove the PCBA, Tesla control board [03125534-xx]. Installation ► Follow the removal instructions in reverse order for i…

100%1 / 150
5 Electrics
5.7 Replacing the PCBA JTF-ML2 Control Board
132 Service Manual SIPLACE JTF-ML2 08/2017
Installation
Follow the removal instructions in reverse order for installation.
NOTICE
Correct orientation
One hole is smaller than the other. Make sure to install the correct orientation.
See also
2 Replacing the Light Aperture [}131]
5.7 Replacing the PCBA JTF-ML2 Control Board
Parts, Equipment and Tools
Standard tools
PCBA Tesla control board [03125534-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the tower from the machine (see 2.1.2 "Removing Tower from Machine" [}21]).
Remove the top cover (see 2.1.3 "Removing Tower Top Cover" [}25]).
Remove all cables from the PCBA, JFT-ML2 con-
trol board [03125534-xx].
1. X22; X8; X7; X6; X5
2. X16; X15
3. X23
4. X18; X19; X17
5. X4
Remove the six screws ISO 4762 - M 3 x 6-A2-70
[03042541-xx] (1).
5 Electrics
5.8 Replacing the Reflective Sensor Cable
Service Manual SIPLACE JTF-ML2 08/2017 133
Remove the PCBA, Tesla control board
[03125534-xx].
Installation
Follow the removal instructions in reverse order for installation.
5.8 Replacing the Reflective Sensor Cable
Parts, Equipment and Tools
Standard tools
Cable, reflective sensor, common [03146661-xx]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
Remove the conveyor from the machine (see 2.1.1 "Removing Conveyor from Ma-
chine" [}17]).
Remove the four screws DIN EN ISO 7380-M3 x
5-A2-70 [03045193-xx] (1).
Remove the Conveyor motor cover [03145679-
xx] (2).
5 Electrics
5.8 Replacing the Reflective Sensor Cable
134 Service Manual SIPLACE JTF-ML2 08/2017
Remove all the cables necessary.
Remove the five screws ISO 7380-2 M 3 x 6-
A2-70 [03099571-xx] (1).
Remove the two screws ISO 7045 - M2 x 4-
A2-50-H [03010197-xx] on the Cable, reflective
sensor, common [03146661-xx].
Remove the Cable, reflective sensor, common
[03146661-xx].
Installation
Follow the removal instructions in reverse order for installation.