00198377-01_SM_JTF-ML2_en.pdf - 第52页
3 Tower Mechanics 3.8 Replacing the Door Guide Strip 52 Service Manual SIPLACE JTF-ML2 08/2017 3.8 Replacing the Door Guide Strip Parts, Equipment and Tools ● Standard tools ● Door guide strip [03133492-xx] Removal ► Swi…

3 Tower Mechanics
3.7 Replacing the Door Insert Lock
Service Manual SIPLACE JTF-ML2 08/2017 51
► Remove the cable tie (1).
► Remove the two screws ISO 4762 - M 4 x 16-
A2-70 [03042507-xx] (2).
► Remove the Transponder safety switch STR1
[03143849-xx],
Transponder safety switch STR1 part of door safety
switch [03158838-xx].
Door insert lock cpl. [03147017-xx]
Installation
► Follow the removal instructions in reverse order for installation.

3 Tower Mechanics
3.8 Replacing the Door Guide Strip
52 Service Manual SIPLACE JTF-ML2 08/2017
3.8 Replacing the Door Guide Strip
Parts, Equipment and Tools
●
Standard tools
●
Door guide strip [03133492-xx]
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
In case remove the tower from the machine (see 2.1.2 "Removing Tower from Machine" [}21])
► Open the door.
► Remove the six screws DIN EN ISO 7380-M3 x 6-
A2-70 [03045194-xx] (1).
► Remove the two Door guide strips [03133492-xx] (2).
Door without Door guide strips [03133492-xx].
Door guide strips [03133492-xx]

3 Tower Mechanics
3.9 Replacing the Door Lock Stop Block
Service Manual SIPLACE JTF-ML2 08/2017 53
Installation
► Follow the removal instructions in reverse order for installation.
3.9 Replacing the Door Lock Stop Block
Parts, Equipment and Tools
●
Standard tools
●
Door lock stop block [03145840-xx]
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}11].
► Open the door.
► Remove the screw ISO 4762 - M 3 x 20-A2-70
[03042547-xx] (1).
► Remove the Transponder safety switch STR1 ac-
tuator (part of door safety switch [03158838-xx])
(2).
► Remove screw DIN EN ISO 7380-M3 x 6-A2-70
[03045194-xx] (1).
► Remove Door lock stop block [03145840-xx] (2).