70 Issue 2 , Mar 18 iTAC option testing on the printer Objective HO 19 : Carry out all the steps in DEK Test Scenario and record the result Variant 1: Variant 1 Step Step Action Description Expected Result Actual Result …

69
Issue 2, Mar 18
Note: For Work Order handling, route A, B works with assign and merge, route D works with
Process Interlocking.
Is Printer 1
st
machine on the line connected to the iTAC? (Assign/Merge or Interlocking)
iTAC option is applicable only for machines with standard and HTC conveyor. It is not compatible
with machine fitted with RTC conveyor. HTC conveyor should be used ideally in 1 stage mode for
inroad conveyor – difficulties to remove PCB from inroad conveyor. 3 stage mode could be used only
if the remote barcode reader is 100% reliable.
iTAC is not compatible with APC (APC is merged into SP16, but iTAC RTX is based on SP15)
Which remote and handheld scanner will be used?
This has to be pre-agreed with customer prior purchase order. Customer has to be aware of 1 serial
port availability on machine PC as well – if wish to use separate remote scanners for the Top &
Bottom side, the scanners have to be connected in daisy chain mode or similar requiring only one
RS232 port.
Customer has to be aware of fixed setting of COM Port (slow baud rate).
Type of the panel barcodes (label or laser edged), size and density should be clarified as well.
It should be decided about barcode format for material & equipment - - Barcode Parameters based
on machine file or product file?
Equipment based on P/N or equipment description?
Will be used standard MES key and product identification in recipe?
NOTES:

70
Issue 2, Mar 18
iTAC option testing on the printer
Objective HO 19: Carry out all the steps in DEK Test Scenario and record the result
Variant 1:
Variant 1
Step
Step Action Description
Expected Result
Actual Result
1
Top side.Assign & upload state
(PASS/PASS) PCB for the laser
marking machine. Activate WO on
the line. Load correct program for
PN activated in iTAC
Unverified (red cross) equipment
and material
2
Check iTAC server on TR \ MIS -
Work order \ Order
No material should be setup on the
line and no equipment rigged on the
WO
3
Open cover and scan required
equipment & material
All equipment and material should
be verified (green tick)
4
Check iTAC server on TR \ MIS -
Work order \ Order
scanned material should be setup
on the line and scanned equipment
rigged on the WO
5
Activate setup of current WO
WO should be activated
6
Scan (PASS/PASS) PCB on
upline conveyor
PCB should be accepted by
machine
7
Place PCB with no barcode on
upline conveyor
PCB should be rejected by machine
due to missing barcode
8
Scan PCB with barcode which is
not assigned to the laser marking
machine
PCB should be accepted by
machine
9
Assign & upload state
(PASS/FAIL) PCB for the laser
marking machine. Scan
(PASS/FAIL) PCB on upline
conveyor
PCB should be rejected by machine
10
Assign & upload state
(PASS/SCRAP) for multiple PCB
for the laser marking
machine.Scan (PASS/SCRAP)
PCB on upline conveyor
PCB should be accepted by
machine
11
Assign & upload state (SCRAP)
for multiple PCB for the laser
marking machine.Scan (SCRAP)
PCB on upline conveyor
PCB should be rejected by machine
12
Bottom side.Change iTAC plugin
for bottom side, load
corresponding program. Verify
Items.
All equipment and material should
be verified (green tick)

71
Issue 2, Mar 18
Check iTAC server on TR \ MIS -
Work order \ Order
scanned material should be setup
on the line and scanned equipment
rigged on the WO
13
Upload state (PASS/PASS) PCB
for the SPI Scan (PASS/PASS)
PCB on upline conveyor
PCB should be accepted by
machine
14
Create new recipe assigned to
Recipe dedicated machine. Kill
DEK software and modify
"iTACmdaConfiguration.xml"
accordingly. Reboot DEK
software. Verify all items, Scan
(PASS/PASS PCB on upline
conveyor
PCB should be accepted by
machine
15
Upload state (PASS/FAIL) PCB
for the SPI Scan (PASS/FAIL)
PCB on upline conveyor
PCB should be rejected by machine
16
Upload state (PASS/SCRAP)
PCB for the SPI Scan
(PASS/SCRAP) PCB on upline
conveyor
PCB should be accepted by
machine
17
Upload state (SCRAP) PCB for
the SPI Scan (SCRAP) PCB on
upline conveyor
PCB should be rejected by machine