12 Production Tools / Station and Line Con figuration User Manual Line Compu ter UNIX 12.1 Configuration Ed itor Software Version 502.xx 10 /2000 Issue 366 I t I I Fig. 12.1.4 Machine Options Editor "Station HS-180&…

100%1 / 600
User Manual Line Computer UNIX 12 Production Tools / Station and Line Configuration
Software Version 502.xx 10/2000 Issue 12.1 Configuration Editor
365
I
t I I
- PCB Centering -> MVS340 selection of image processing system type for PCB centering
PCB Centering -> MVS ("MVS" and "MVS340" for all-SIPLACE" lines,
PCB Centering -> MVS1000 MVS "M10000" for SIPLACE lines with HS-180)
- Comp Centering -> MVS340 selection of image processing system type for component
Comp Centering -> MVS centering ("MVS" and "MVS340" for "all-SIPLACE" lines,
Comp Centering -> MVS1000 "M10000" for SIPLACE lines with HS-180)
- PCB reference corner [mm] Setting of the PCB stopper position (unique to HS-50)
The following stopper positions may be set for the processing
area 2:
1 : 0,000 (default setting)
2 : 47,000
3 : 87,000
4 : 137,000
5 : 207,000
6 : 237,000
7 : 267,000
8 : 297,000
NOTE
On account of the change in the stopper positions it is now possible to process in an HS50 placement sta-
tion also exceptionally long PCBs up to a size of 24"x18".
- Whispering down the line Fiducials defined as inkdots are only measured at the
first station. The measuring result is transferred to the
subsequent stations.
- with global fiducials Fiducials for PCB position recognition (including the fiducials
for inkdots) are only measured at the first station.
NOTE
The "Whispering down the line" (WDTL) option can only be used in more recent SIPLACE machine
generations such as 80S20 or 80F
4
(and later versions, with exception of HS-50).
It serves to reduce machine ancillary times (measuring times) during the processing of PCBs since the
position of all fiducials is determined only at the first station of a line.
At the subsequent stations merely two fiducials are measured, and the position of any other fiducials
that may be required is calculated from the measuring results transferred from the preceding station
in each case.
Only if the button for "Whispering down the line" is activated can the button "with global fiducials" be
activated in addition.
The setting of the "Whispering down the line" option must be the same on all stations.
12 Production Tools / Station and Line Configuration User Manual Line Computer UNIX
12.1 Configuration Editor Software Version 502.xx 10/2000 Issue
366
I
t I I
Fig. 12.1.4 Machine Options Editor "Station HS-180"
POSSIBLE SETTINGS for the machine option "HS-180 Station" (standard machine)
- Conveyor -> Ultrasonic PCB tracking with/without ultrasonic detecting system
- Conveyor -> PCB barcode PCB recognition with/without barcode
- Conveyor -> Track barcode component type recognition for track-related refilling
with/without barcode
- PCB conveyor -> fast setting the PCB conveyor to the fast or slow mode
PCB conveyor -> slow
setting area
User Manual Line Computer UNIX 12 Production Tools / Station and Line Configuration
Software Version 502.xx 10/2000 Issue 12.1 Configuration Editor
367
I
t I I
12.1.3.4 Main Window of Machine Options Editor "Head"
Fig. 12.1.5 Machine Options Editor "Head" (location "Gantry HS-180")
POSSIBLE SETTINGS for the machine option "Head"
- Camera for PCB centering PCB centering with/without camera
- Camera for Ink spot ink dot recognition with/without camera
- Head level selection of head mounting position in 3 stages
(does not apply to SIPLACE head) (14.60, 22.60 and 30.60 mm)
depending on the respective head type
(e.g. "Level 3" for 30mm head)
setting area
settings for"Head level"
(does not apply to
"SIPLACE head)