KE-2030使用说明书.pdf - 第128页
4 – 29 4.3.13 Matrix Copy For Placement dat a, this comm and inserts t he data read into t he memor y buffer with the [Cut] or [ Copy] command at or befor e the cursor posit ion. For Pick dat a, this comm and copies the …

4 – 28
4.3.12 Change Component Name
This command allows you to change a component name.
When you change a component name only, the name is changed and the contents
remain the same. When you select the [Change Component Name] command,
the following dialog box appears on the screen.
The component name before changed is displayed in the Edit box “Component
Name: from”. The component name before changed is displayed and highlighted
in the Edit box “Component Name: to”.
• Enter a new component name in the Edit box “Component Name: to”, then
click the <OK> button. The component name is changed to a new name you
specified. When you click the <CANCEL> button, the component name is not
changed, then the machine returns to the screen displayed before you select
the [Change Component Name] command.
• If the same component name already exists, the following dialog box appears
on the screen.
Note: This command can be selected on the following screens:
•
Component list
•
Component form
•
Pick data All component names are replaced with the specified
name.
•
Vision data All component names are replaced with the specified
name.
•
Placement data All component names are replaced with the
specified name.

4 – 29
4.3.13 Matrix Copy
For Placement data, this command inserts the data read into the memory buffer
with the [Cut] or [Copy] command at or before the cursor position.
For Pick data, this command copies the line at which the cursor is located, then
inserts the copied line to the next line. After this command is executed, the cursor
moves to the leftmost input field of the newly copied line.
When you specify the items “No. of copies X”, “No. of copies Y”, “X Pitch”, and “Y
Pitch”, the machine copies the data in a matrix with adding or subtracting the
entered valued to/from the placement position in the X direction and that in the Y
direction respectively.
After the [Matrix Copy] command is executed, all of the component IDs are
changed to “#”.
If there is no data in the memory buffer, this command is disabled.
For Pick data, this command can be executed for tray components (fed with a tray
holder or ATS only).
For Pick data, you cannot execute this command by selecting two or more data
records.
① No. of copies X: specifies the number of times for copying in the X direction.
The default value is “1” for both Placement data and Pick data.
② No. of copies Y: specifies the number of times for copying in the Y direction.
The default value is “1” for both Placement data and Pick data.
③ X Pitch: sets the amount to increment or decrement the placement or pick
position in the X direction.
The default value is “0.00” for both Placement data and Pick data.
④ Y Pitch: sets the amount to increment or decrement the placement or pick
position in the Y direction.
The default value is “0.00” for both Placement data and Pick data.
⑤ OK: executes the paste operation.
⑥ Cancel: cancels the paste operation.

4 – 30
Example of the [Matrix Copy] command result
When this command is successfully executed
(For Placement data)
Component IDs X Y Angle Component name
(Screen image)
R1 5.00 10.00 45.00 1608-A
R2 10.00 10.00 0.00 1608-A
No. of copies
X: 3
X Pitch:
0.5
No. of copies
Y: 1
Y Pitch:
1
R 5.00 10.00 45.0 1608-A
R2 10.00 10.00 0.00 1608-A
# 5.50 10.00 45.00 1608-A
# 10.50 10.00 0.00 1608-A
# 6.00 10.00 45.00 1608-A
# 11.00 10.00 0.00 1608-A
# 6.50 10.00 45.00 1608-A
# 11.50 10.00 0.00 1608-A
# 5.00 11.00 45.00 1608-A
# 10.00 11.00 0.00 1608-A
# 5.50 11.00 45.00 1608-A
# 10.50 11.00 0.00 1608-A
# 6.00 11.00 45.00 1608-A
# 11.00 11.00 0.00 1608-A
# 6.50 11.00 45.00 1608-A
# 11.50 11.00 0.00 1608-A
− The copied block is inserted above the specified line.
− All of the component IDs become “#”.
− The input focus moves to the first component ID of the inserted block.
(For Pick data)
Component Pack Tray feeder Angl Sply Pos Type lane X1 Y1 Z X2 Y2 X3 Y3
name
R1 Tray ATS 0 Rear 50 * 1 436.30 -47.70 5.00 436.30 -27.70 456.30 -47.70
(Screen image)
No. of copies
X: 2
X Pitch:
100
No. of copies
Y: 1
YPitch:
: 50
R1
トレイ
ATS 0
リア
50 * 1 436.30 -47.70 5.00 436.30 -27.70 456.30 -47.70
R1
トレイ
ATS 0
リア
50 * 1 536.30 -47.70 5.00 536.30 -27.70 556.30 -47.70
R1
トレイ
ATS 0
リア
50 * 1 636.30 -47.70 5.00 636.30 -27.70 656.30 -47.70
R1
トレイ
ATS 0
リア
50 * 1 436.30 2.30 5.00 436.30 22.30 456.30 2.30
R1
トレイ
ATS 0
リア
50 * 1 536.30 2.30 5.00 536.30 22.30 556.30 2.30
R1
トレイ
ATS 0
リア
50 * 1 636.30 2.30 5.00 636.30 22.30 656.30 2.30
− Only when “Tray” is selected as the package and the “Holder” or “DTS” is selected as the “Tray Feeder”,
you can execute the [Matrix Copy] command.
− You cannot copy two or more records.
− The copied block is inserted above the specified line.
− The input focus moves to the beginning of the inserted block.
Y Pitch:
O
X Pitch:
O
X Pitch:
Y Pitch: