KE-2030使用说明书.pdf - 第596页
9 − 3 (2) Set ting t he pause time and number of t imes - Set the time spent for stopping warming -up operation and t he number of times you are to perf orm warming- up operations. - T he available values vary depending …

9 − 2
9.2 Warming up
9.2.1 Warm-up initial screen
When you select the [Warming Up] command on the [Maintenance] menu invoked
from the menu bar of the main menu, the following Warm-up initial screen appears.
Figure 9.2.1 Warm-up dialog box
When you press the <START> switch, the warm-up operation starts.
9.2.2 Setting the conditions for warming-up operation
When you click the <SET> button, the following "Setting" dialog box appears on the
screen.
Figure 9.2.2.1 Setting dialog box
(1) Device to be warmed up
Select the device to be warmed up: Axis, Cnvr. (Conveyor) and/or MTC.
If the MTC is not checked on the "Device enable" menu invoked from the Machine
Setup menu, the item "MTC" is disabled, and you cannot select it.
Any of these devices is not selected, the <OK> button is disabled.
Initial setting: Axi

9 − 3
(2) Setting the pause time and number of times
- Set the time spent for stopping warming-up operation and the number of times
you are to perform warming-up operations.
- The available values vary depending on the warming-up operation terminating
conditions.
- Time: 0 to 9999 (minutes)
Note: When "0" is set, warming-up operation will not finish until you suspend it.
- Number: 1 to 999999
●
Initial value: 0
(3) Setting the condition for terminating warming-up operation
- Select the condition for terminating warming-up operation: Time or Number.
●
Initial setting: Time
(4) Setting the speed
- Set the speed of an axis.
- You can select high speed (High) or middle speed (Middle).
●
Initial setting: Middle
Note: The axis speed is fixed to “Middle” for the standard specifications
(see Figure 10.2.2.1.)
Contact us or your dealer for the details on the speed setting (variable).

9 − 4
9.2.3 Warming-up operation
During warming-up, a screen shown below appears.
Figure 9.2.3.1 "Under warm-up" dialog box
(1) Axis
The X, Y Z and theta axes motors and the ATC slide plate operate.
Note that warming-up operation finishes when the ATC slide plate opens and
closes ten times.
(2) Cnvr.
The PWB transfer motor, back-up table, stopper pin, edge reference cylinder
(option), and PWB check cylinder (only for a KE-2030) operate.
Note that warm-up operation finishes when each of the stopper pin, edge
reference cylinder and PWB check cylinder turns on, then off four times.
(3) MTC
The shuttle operates.
When you press the <STOP> switch or click the <STOP> button displayed on the
dialog box above, the confirmation dialog box appears on the screen.
When you click the <Yes> button, warming-up operation terminates.