KE-2030使用说明书.pdf - 第670页
11 − 22 enable” menu invoked f orm the Machine Setup menu.
11 − 21
④ Stop when feeder pitch shift is detected.
− Using the check box, set whether to check to see if a feeder component
pick-up position is shifted from the regulated position.
− When you check the check box of this option, the radio button “Stop when
feeder pitch shift is detected.” is enabled on the Component data screen.
⑤ Non-stop operation
− Using this check box, set whether to perform the Non-stop operation or
not.
− When you check the check box of this option, the non-stop operation
function is enabled.
− When feeders are assigned to the front and rear sides symmetrically with
the Program Editing utility, the non-stop operation gets executable.
When you check the check box of this option, the system performs the
non-stop operation.
⑥ Alternate
− When you enable the “Non-stop operation” function, this check box is
enabled. When enabled, check this check box to execute the alternate
production mode function in Non-stop operation mode.
− When you check this check box, Alternate Production mode is enabled.
− The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation”, enabled or disabled.
⑦ Non-stop operation (MTC) (Not available for a KE-2030)
− Using this check box, set whether to perform the Non-stop operation
(MTC) or not.
− When you check the check box of this option, the non-stop operation
function is enabled.
− This item is enabled only if “TR6D” is selected as an MTC on the “Device
enable” menu invoked form the Machine Setup menu.
⑧ Alternate (MTC) [Not available for a KE-2030]
− When you enable the “Non-stop operation [MTC]” function, this check box
is enabled. When enabled, check this check box to execute the alternate
production mode function in MTC Non-stop operation mode.
− When you check this check box, MTC Alternate Production mode is
enabled.
− The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation [MTC]”, enabled or disabled.
⑨ Non-stop operation (MTS) (Not available for a KE-2030)
− Using this check box, set whether to perform the Non-stop operation (MTS)
or not.
− When you check the check box of this option, the non-stop operation
function is enabled.
− This item is enabled only if “TR5D” is selected as an MTS on the “Device
11 − 22
enable” menu invoked form the Machine Setup menu.
11 − 23
⑩ Alternate (MTS) [Not available for a KE-2030]
− When you enable the “Non-stop operation [MTS]” function, this check box
is enabled. When enabled, check this check box to execute the alternate
production mode function in MTS Non-stop operation mode.
− When you check this check box, MTS Alternate Production mode is
enabled.
− The status of this check box, checked or not checked, is not affected by
the setting of the “Non-stop operation [MTS]”, enabled or disabled.
⑪ Non-stop operation (DTS) (Not available for a KE-2030)
− Using this check box, set whether to perform the Non-stop operation (DTS)
or not.
− When you check the check box of this option, the non-stop operation
function is enabled.
− Automatically setting the number of DTS components when replenished
If you press the <SUPPLY> switch to replenish components, then press
the <SUPPLY> switch again to release Component Supplying mode while
the system is producing a PWB in Non-stop mode, this function
automatically sets the number of components that are located on the level
you replenished so that it can indicate the level is fully replenished.
− This item is enabled only if “DTS” is enabled on the “Device enable” menu
invoked form the Machine Setup menu.
⑪ Enable Auto Compo. presence check of MTC (Not available for a KE-2030)
− Using the combo box, select the check operation of MTC components
when picked up (“a.” is selected as the default).
a. Do not check: the system does not check any component.
b. Read file the system checks components when a production
program file is changed.
c. Supply component: the system checks components when components
finish being replenished by your pressing the
Supply key of an MTC.
− When you select “Read file” or “Supply component”, the system checks to
see if there is any component on a tray with the HMS located inside an
MTC when it picks up a component from a tray of the MTC that is
replenished fully. Then, the system starts picking up a component from
where a component is actually located.
− When you select “Do not check”, the system always starts picking up
components from the first component of a tray when the tray is replenished
fully.
− This item is enabled only if “TR6D” is selected as an MTC on the “Device
When you validate the selected item(s), click the <OK> button. If you do not want to
set any option, click the <CANCEL> button.
☞