8 − 46 (4) Contr ol but ton Each contr ol item can be executed with the contr ol button. The display of the contr ol buttons vary depending on t he control it em you selected. 1) T ape f eeding action This item feeds a t…

8 − 45
When selecting “Direct knock action” in the control items, select the position of
the pin to be controlled from the control side (using the radio button).
(3) Kind of feeder
When selecting “Tape feeding action” as the control item, select the tape width
and feed pitch from the combo box.
This item cannot be set when the control item “Direct knock action” is selected.
The following list appears when you press the ALT key and ↓ key at the same
time.
Tape width
The available feed pitches vary depending on the tape width you selected.

8 − 46
(4) Control button
Each control item can be executed with the control button.
The display of the control buttons vary depending on the control item you
selected.
1) Tape feeding action
This item feeds a tape.
When the control item “Tape feeding action” is checked, select the< EXEC>
button, or press the F3 key to control the tape feed.
2) Direct knock action
This item executes knock operation per feeder bank.
When the control item “Direct knock action” is checked, select the< “EXEC>
button, or press the F3 or F4 key to control the direct knock.
3) FPI cont. (Independent)
This item turns on or off the feeder position indicator.
When the control item “FPI cont.” is checked, select the <ON>, <OFF>,
<ON/OFF> or <BLINK> button, or press the F3, F4, F5 or F6 key.
4) FPI cont. (All)
This item turns on or off the feeder position indicators on the front feeder
bank or rear feeder bank.
When the control item “FPI cont.” is checked, select the <ON>, <OFF>,
<ON/OFF)> or <BLINK> button, or press the F3, F4, F5 or F6 key.

8 − 47
8.5 Others
8.5.1 ATC control
When you select the [Others] command from the [Ctrl] menu, then the [ATC control]
command, the following ATC control dialog box appears on the screen.
Figure 8.5.1.1 ATC control screen
(1) Control unit
Select the unit to be controlled from the combo box.
When you press the ALT key and down arrow key at the same time, the
following list appears on the screen.
Note: You can select “R-ATC” only when you use a KE-2030.