4 – 35 4.4 Data This comm and menu provides the comm ands which allow s you to move to the Editing screen f or each type of dat a: PW B data, Placement dat a, Component data, and Pick data, and those f or displaying each…

100%1 / 723
4 – 34
If you specify the mark data already registered, the following overwriting
confirmation message appears on the screen.
Overwriting mark confirmation message
To overwrite mark data, click the <Yes> button.
4 – 35
4.4 Data
This command menu provides the commands which allows you to move to the Editing
screen for each type of data: PWB data, Placement data, Component data, and
Pick data, and those for displaying each type of data completion status, and those for
checking to see if each data record is completed correctly by comparing to the
configuration set on the Setup screen.
4.5 PWB data
4.6 Placement data
4.7 Component data
4.8 Pick data
The commands above display the corresponding type of data and switch the input
screen for each type of data.
See the Section on each type of data for details.
Other method for switching the data input screen
In addition to the method described above, you can switch between each type of data
input screens as described below.
Press the F6 key while holding the CTRL key or press the TAB key while holding
the CTRL key to move to the next data window. Press the F6 key while
holding the SHIFT and CTRL keys or press the TAB key while holding the CTRL
and TAB keys to move to the previous data window.
Click each data title button displayed on the bottom of the screen.
4 – 36
4.5 PWB Data
4.5.1 Basic setting
After the Program Editing utility starts up or when you select [Create new] on the File
menu, a program name becomes “UNTITLED”, and the PWB data basic setup screen
as shown in the figure below appears initially.
Use the "PWB ID" edit box to set the PWB ID, and use the corresponding radio button
to set the positioning method, PWB configuration, BOC type and bad mark type.
To set each item, move the cursor over the desired item with a track ball, then click
the button of the desired setting with the left button.
Description of each menu item
(1) PWB ID
Up to 32 alphanumeric characters and symbols can be entered. However, note
that only numbers or only symbols cannot be entered. They shall be combined
with alphabetic characters. When reading the production program, the PWB ID
is displayed as well as the file name of the production program, so enter an ID
which is easy to understand.
(2) Reference method
1) Hole reference
The PWB has positioning holes, and the reference pins are inserted in the
holes to hold the PWB.
2) Shape reference
After the PWB touches the stopper, the edges of the PWB are fixed
mechanically to hold the PWB.