CP-7[732-742]-series Mechanical Reference(2.9E).pdf - 第144页

2. Remove the power supply unit and power supply unit cover. The removal procedure varies among different types of power supply unit. 3. Disconnect the UV lamp harness (M1LP3A, 4A) connectors from the power supply unit. …

100%1 / 251
C7SM3091E
Type 1 Type 2 Type 3
Connector
ConnectorConnector
C7SM3087E
Sticker
C7SM3095E
Tie wraps
C7SM3092E
Connector
(M1LP3A)
Connector
(M1LP3A)
Connector
(M1LP4A)
Connector
(M1LP4A)
Type 1, 2
Type 3
C7SM3089E
Type 1 Type 2
Type 3
Cover
CoverPower supply unit
Power supply unit
Power supply unit
Cover
C7SM3094E
UV lampUV lamp
Bolt
M4 x 10
Bolt
M3 x 6
Bolt
M3 x 8
Bolt
M3 x 8
Type BType A
C7SM3093E
Nozzle holder