1.5 Cleaning the Camera Glass (Weekly)
Point
The camera glass should be cleaned once a week to ensure that a clear image is being
acquired. This also contributes to stable vision processing and part pick-up operations.
Procedure
WARNING
Be sure to turn the main power off before performing this
procedure.
Use a soft brush (such as those used to clean camera lenses) to clean the camera glass. If
the glass is badly soiled, use a commercially available glass cleaner.
CAUTION
Take care to not bend any nozzles.
Do not place excessive pressure on the camera cover
glass, which is thin and breaks easily.
C7SM3010a
Camera glass
Part 3 Chapter 1 Cleaning
Edition 2.9 3-1-5 CP-7 series Mechanical Reference
1.6 Cleaning the Filter Regulator (Weekly)
Point
The air that flows through the system’s air lines must always be clean. A soiled filter
regulator makes it impossible to supply clean air, and can cause equipment failure.
Procedure
CAUTION
Be sure to turn the air supply off before performing this
procedure.
Be sure to turn the air supply off and to release the air pressure in advance.
1. Close the air inlet valve lever and cut the external air-supply.
2. Reduce the pressure in the air hose.
After disconnecting the air hose, return the valve lever slowly to the position
indicated in the illustration below to expel the air from the air inlet.
3. Close the valve lever again when the air has been fully expelled.
Valve lever
Air
Air hose
Valve lever
Close
Part 3 Chapter 1 Cleaning
Edition 2.9 3-1-6 CP-7 series Mechanical Reference
Next remove the filter case and clean the filter element.
1. Disconnect the drain hose from the regulator if there is any.
2. Remove the filter case.
While pressing the lock down, turn to remove the filter case.
3. Remove the drainage collected in the filter case and wash the case with neutral
detergent.
4. Remove and clean the element.
Note: The element should be replaced every 2 years.
Assemble the filter regulator after cleaning, attach the air-hose, and open the valve lever
fully.
O-ring
O-ring
Lock knob Lock knob
Filter case
Filter case
C7SM3002b
A
AB
B
A
B
A
B
Filter regulator
AW3000-02-BD
Mist separator
AFM3000-02-D
Model : 111585
Manufacturer : SMC
Filter element
Model : 630617
Manufacturer : SMC
Element assemby
<CP-732E>
<CP-742ME>
<CP-742E>
Part 3 Chapter 1 Cleaning
Edition 2.9 3-1-7 CP-7 series Mechanical Reference