Notes: Part 6 Chapter 1 Leveling the Machine Edition 2.3 6-1-4 CP-7-series Mechanical Reference

100%1 / 251
C7SM5001-4
Lock nut
Leveling bolt
Leveling sheet
Anti-vibration pad
125
125
125
125
(mm)
C7SM5001-3a
538696778
<CP-742E>
518
125
730 518 778 696 538 730
125
150
150
100 549 510 455 100
100 593 466 455
Part 6 Chapter 1 Leveling the Machine
Edition 2.3 6-1-3 CP-7 series Mechanical Reference
Notes:
Part 6 Chapter 1 Leveling the Machine
Edition 2.3 6-1-4 CP-7-series Mechanical Reference
2. Connecting the Air Supply
Point
Connect the air hose to the machine, and adjust the regulator to the prescribed air
pressure.
Procedure
1. Connect the air hose to the machine’s air inlet located on the front of the machine.
2. Raise the filter regulator knob to release the lock.
3. Turn the handle to adjust the air pressure until the gauge reads 0.5 MPa
(5kgf/cm
2
).
Note: A digital pressure gauge is attached to the rear cover.
4. Press the filter regulator knob down to engage the lock.
Note: The air hose is not supplied with the machine.
• 30SH ( for 3/8" hose)
• 20SH ( for 1/4" hose)
• 40SH ( for 1/2" hose)
Socket
0.5 MPa (5 kgf/cm )
2
Hose
20PM Plug
Handle
Knob
C7SM5002a
Air inlet
<CP-732E> <CP-742ME>
Air inlet
Air inlet
Digital pressure gauge
Digital pressure gauge
Digital pressure gauge
<CP-742E>
Part 6 Chapter 2 Connecting the Air Supply
Edition 2.3 6-2-1 CP-7-series Mechanical Reference