UPS (Uninterrupted Power Supply Unit)
The UPS unit is positioned in the transformer box at the rear of the machine. Under
normal circumstances, the power supply from the UPS is cut automatically when the
machine is shut down. However, if the machine is not operating correctly, the power
from the UPS unit may not always be cut. As a safety precaution when performing any
kind of electrical maintenance work, always set the switch on the UPS unit to off after
also cutting the main power supply to the machine.
Notes Regarding CP-7-series Machines Operation
Absolute encoders are used on all servo motors on the machine. Differences with other
machine types are listed below.
The harness connectors on the servo motors should not be removed. If a harness
connector is removed it will be necessary to recalibrate Proper data.
Proper data measurement is also required at the following times.
After replacing the motor
After removing the cable connector from between the motor and servo amp
If the backup battery within the servo amp is dead
Zero setting is not required on the machine.
C7SM1038a
Power switch
UPS (Uninterrupted Power Supply Unit)
Part 1 Chapter 2 Functions of Each Part
Edition 2.4 1-2-4 CP-7 series Mechanical Reference
3. Sensor Positions
XY-table
X/Y-axis
C7SM1T01
SX009
SX00A
SX011
SX012
X_AXIS_+OT
X_AXIS_-OT
Y_AXIS_+OT
Y_AXIS_-OT
Sensor No.
SIGNAL NAME
SX009
SX011
SX012
SX00A
C7SM1021a
Part 1 Chapter 3 Sensor Positions
Edition 2.4 1-3-1 CP-7 series Mechanical Reference
Z-axis
C7SM1T02
SX019
SX01A
X05C
X05E
Z_AXIS_+OT
Z_AXIS_-OT
XY-TABLE LOADING HEIGHT CHECK
MAIN-LIFTER MIDDLE OT
Sensor No.
SIGNAL NAME
SX01A
X05E
SX019
X05C
C7SM1022a
Part 1 Chapter 3 Sensor Positions
Edition 2.4 1-3-2 CP-7 series Mechanical Reference