CP-7[732-742]-series Mechanical Reference(2.9E).pdf - 第168页

1.6.1 Feeder Check Sensor Position Adjustment 1. Press the EMERGENCY STOP button to turn off the 200V power, leaving only the 100V power on. W ARNING Always be sure to cut off the 200V power before carrying out any work.…

100%1 / 251
1.6 Feeder Height Error Detection (Station 1)
Point
To detect the positions of the feeders, two sets of sensors are used at each of the retract
areas. A further pair of sensors are also used at the pickup position, bringing the total
number to five.
A dedicated jig is used to position these sensors. The sensitivity of the sensors must also
be adjusted.
Note: The above figure represents device table one, but the same arrangement can also be found
on device table two.
The jig used to adjust the sensor positions is shown below.
Positioning jig body
(ADCPJ8020)
Block
(DCPJ0040)
Block
(DCPJ0050) < For CP-732E/CP-742ME >
Block
(DCPJ0060)
Block
(DCPJ0070)
Block
(DGPJ5070) < For CP-742E >
C7SM4049b
Feeder check sensor
(D1 retract area upper direction check)
Feeder check sensor
(D1 retract area lower direction check)
Feeder check sensor
(Pickup area upper direction check)
C7SM4022a
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-17 CP-7 series Mechanical Reference
1.6.1 Feeder Check Sensor Position Adjustment
1. Press the EMERGENCY STOP button to turn off the 200V power, leaving only the
100V power on.
WARNING
Always be sure to cut off the 200V power before carrying
out any work.
2. Set the positioning jig body on a feeder pallet.
3. Use the inching keys to position the feeder pallet and bring the positioning jig
body within the vicinity of the sensor in question.
4. Attach a block appropriate for each sensor within the jig and then adjust the
sensor position.
Pick-up Area
Block
(DCPJ0040)
Sensor bracket
C7SM4050a
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-18 CP-7 series Mechanical Reference
D1, D2 Retract Area (Upper direction check)
Inner sensor
Outer sensor
<CP-732E, CP-742ME>
<CP-742E>
C7SM4057a
Sensor bracket
Block (DGPJ5070)
Block (DCPJ0050)
C7SM4051a
Sensor bracket
Block
(DCPJ0040)
Sensor bracket
C7SM4050a
Part 4 Chapter 1 Station Adjustments
Edition 2.4 4-1-19 CP-7 series Mechanical Reference