Safety Guidelines Edition 2.6 6 CP-7 series Mechanical Reference Check the machine monitor and the target axes while manually operating the machine. ● When operating the machine, carefully follow the instructions that ar…

Safety Guidelines
Edition 2.6 5 CP-7 series Mechanical Reference
Exchange the halogen lamp only after it has cooled
down.
● When turned on, halogen lamps will reach high temperatures,
resulting in skin burns when touched. To exchange a halogen
lamp, turn off the power and allow the lamp to cool off sufficiently.
Do not wear gloves made of cloth when operating the
machine.
● Rubber gloves will tear when caught by the machine and prevent
hands from being drawn into the machine. Gloves made of cotton
or similarly strong material may cause hands to be drawn into the
machine.
Long hair should be tied back.
● Long hair may get caught in running machines.
Hair should be kept short or tied back so that it does not get caught
in the machine.
Turn off the air supply when carrying out maintenance
on cylinders, valves, and filters.
● Removing cylinders, valves, or filters without turning the air supply
off, may cause parts or particles to be propelled into the eyes.
● Be sure to turn off the air supply when carrying out maintenance on
cylinders, valves, and filters.
Be sure to wear protective glasses.
● Be sure to wear protective glasses.
[Example]
CP-6, 7 nozzles use springs which may be propelled during
disassembly. Be sure to handle the nozzles carefully to prevent eye
injuries.
WARNING

Safety Guidelines
Edition 2.6 6 CP-7 series Mechanical Reference
Check the machine monitor and the target axes
while manually operating the machine.
● When operating the machine, carefully follow the instructions that
are displayed at the machine display.
● Operating the machine without looking at the machine display may
lead to operating errors or result in damage to the machine or
products.
WARNING
CAUTION
Do not operate the machine after removing or disabling
sensors.
● Removing or disabling sensors will disarm the interlock, leading to
collisions and damage to the machine.
Check the machine display to determine whether
HELPS compatible machines are in the middle of
performing changeover.
● During operation in automatic mode on machines equipped with
automatic changeover equipment, it may be difficult to actually see
automatic changeover taking place from the front of the machine.
When a message appears at the machine display, follow the
instructions that are given.
Do not touch the servo amp power terminal for at least
five minutes after turning off the power.
● The servo amp retains a high voltage even after the power has
been turned off. Always wait at least five minutes, and ensure that
the CHARGE lamp is off, before undertaking any work that may
result in contact with the servo amp terminal.
Ensure to use the handle when opening or closing the
safety doors, fences or covers.
● Opening or closing the safety doors, fences or covers without using
the handle may result in injury to the hand.
● Opening or closing the safety doors, fences or covers with force,
without using the handle may result in damage to the machine.

Safety Guidelines
Edition 2.6 7 CP-7 series Mechanical Reference
3. Safety Rules for Individual Machine Types
CP-7-series Machines
WARNING
Do not insert hands or other body parts into the
conveyor inlets.
● Body parts may get caught in the machine resulting in injury.
Do not operate the machine when the front/rear cover
has been removed.
● Body parts may get caught in the machine resulting in injury.
Do not perform cam box maintenance with power to the
machine on.
● Injury may result from electric shock if maintenance on the cam box
is carried out with the power to the machine on.
Caution required if cam is not at its origin (0°).
● Operators must ensure the cam is at its origin (0°) prior to carrying
out any operations on the machine.
If the cam is not at its origin, recoil from springs used to drive the
placing heads may cause unexpected movement which is
potentially dangerous for the operator.
If an emergency stop occurs, the machine stops immediately. In
this case there is a strong possibility that the cam will not be at its
origin.
● If the cam is not at its origin when the machine stops, use the cam
handle to return it to its origin.
Do not stare into the laser beam.
(On machine fittied with laser type fiber
sensors (class 2))
● Exercise extreme caution when working in areas where there is a