CP-7[732-742]-series Mechanical Reference(2.9E).pdf - 第222页
AC Servopack Check List for Troubleshooting Alarm Alarm Name Status Cause Check Item Remedy A.51 Overspeed • Occurs at control power ON. • Occurs at main power ON or when motor is in operation. • Servopack defective. • I…

AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.30 Regenerative
Error Detected
• Occurs at control power ON.
• Occurs at main power ON.
• Servopack defective.
• Wiring to regenerative resistor
defective.
• Servopack defective.
• Incorrect regenerative resistor
wiring.
• Regenerative resistor
disconnected.
• Check the wiring to regenerative
resistor.
• Servopack defective.
• Check that wiring to the
regenerative resistor is proper.
• Check the regenerative
resistance value.
• Replace the Servopack.
• Check the regenerative value
and correct the wiring.
• Replace the Servopack.
• Manually correct the wiring of the
external regenerative resistor.
• Replace the external
regenerative resistor.
A.32 Regenerative
overload
• Occurs at control power ON.
• Occurs at normal operation.
• Servopack defective.
• Parameter Pn600 set value is
not correct when a regenerative
resistor is mounted externally.
• Servopack defective.
• Check that parameter Pn600 set
value is correct.
• Servopack defective.
• Replace the Servopack.
• Set parameter Pn600 correctly.
• Replace the Servopack.
NP1MT002E
A.40 Overvoltage • Occurs at control power ON.
• Occurs at main power ON
or when motor is in operation.
• Servopack defective.
• Excessive power supply voltage.
• Servopack defective.
• Check the AC power supply
voltage. (Is there excessive
voltage variation?)
• Servopack defective.
• Replace the Servopack.
• Set the AC power supply voltage
to a value in the normal setting
range.
• Replace the Servopack.
A.41 Undervoltage • Occurs at control power ON.
• Occurs at main power ON
or when motor is in operation.
• Servopack defective.
• Power supply voltage is
excessively small.
• Servopack defective.
• Power supply variation is large
and power supply is reduced.
• Check the AC power supply
voltage. (Pay attention to
different power supply applied.)
• Servopack defective.
• Check that a momentary power
failure has not occurred.
• Replace the Servopack.
• Set the AC power supply voltage
to a value in the normal setting
range.
• Replace the Servopack.
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-6 CP-7 series Mechanical Reference

AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.51 Overspeed • Occurs at control power ON.
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Incorrect motor wiring.
• Incorrect encoder wiring.
• Servopack defective.
• Check that the motor rotating
direction is correct (phases U, V
and W wiring).
• Servopack defective.
• Replace the Servopack.
• Manually correct the motor
wiring.
• Manually correct the encoder
wiring.
• Replace the Servopack.
A.71
A.72
Overload for
Instantaneous
Maximum Load
Overload for
Continuous
Minimum Load
• Occurs at control power ON.
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Incorrect motor wiring.
(imperfect wiring or connection)
• Incorrect encoder wiring.
(imperfect wiring or connection)
• Servopack defective.
• Check that the connnection is
correct and that the motor wiring
does not have an open phase.
• Servopack defective.
• Excessive load on servo.
• Replace the Servopack.
• Manually correct the motor
wiring.
• Manually correct the encoder
wiring.
• Replace the Servopack.
• Check for excessive load on
components driven by the servo.
NP1MT003E
A.73 Dynamic Brake
Overload
• Servopack defective. • Replace the Servopack.
A.74 Overload of
in-rush Current
Limit Resistor
• Occurs at control power ON.
• Occurs at main circuit
power supply ON/OFF.
• Servopack defective.
• The allowable frequency of
in-rush current limit resistor at
power ON/OFF is exceeded.
• Servopack defective.
• Check that the allowable
frequency of in-rush current limit
resistor (5 times/min) is not
exceeded.
• Check that the Servopack fan is
operating.
• Check that the fan for the control
board is operating.
• Check the ambient temperature
of the Servopack exceeds 35 °C.
• Excessive load on servo.
• Replace the Servopack.
• Reduce the main circuit power
supply ON/OFF frequency to
5 times/min.
• Replace the Servopack.
A.7A Heat Sink
Overheated
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Ambient temperature of the
Servopack exceeds 35 °C.
• Replace the Servopack.
• Set the ambient temperature of
the Servopack to 35 °C or less.
• Check for excessive load on
components driven by the servo.
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-7 CP-7 series Mechanical Reference

AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item Remedy
A.81 Absolute Encoder
Backup Error
• Occurs at power ON.
(Pn002.2 = 0)
When used as absolute
encoder.
• Occurs at power ON.
(Pn002.2=1)
• Turn ON the power supply to the
absolute encoder for the first
time.
• Both PG power supply (+5V)
from the Servopack and the
battery power supply are failed.
• Absolute encoder defective.
• Servopack defective.
• Servopack defective when used
as incremental encoder.
• Check that the absolute encoder
has been set up.
• Check that the power is supplied
to the encoder side.
• Encoder defective at alarm
occurrence even by setting up
the absolute encoder again.
• Servopack defective if nothing is
wrong in the above check.
• Check that the battery is
connected correctly.
• Check that the battery voltage is
not reduced to 2.7 V or less.
• Servopack defective if nothing is
wrong in the above check.
• Set up the encoder.
• Set up the encoder after
restoring the power supply to
the encoder (by replacing the
battery, etc.).
• Replace the encoder.
• Replace the Servopack.
• Replace the Servopack.
NP1MT004E
A.82 Encoder
Checksum Error
• Occurs at power ON or
when motor is in
operation.
• Encoder defective.
• Servopack defective.
• Set up the encoder. Replace
the motor if the alarm occurs
frequently.
• Replace the Servopack.
A.83 Absolute Encoder
Battery Error
• Occurs at power ON.
(Pn002.2=0)
When used as absolute
encoder.
• Imperfect connection or
disconnection of battery.
• Battery voltage is reduced to the
specified value (2.7 V) or less.
• Servopack defective.
• Connect the battery properly.
• Replace the battery and turn
ON the encoder power supply again.
• Replace the Servopack.
• Replace the Servopack.
A.84 Encoder Data
Error
• Occurs at power ON or
when motor is in
operation.
• Sensor in the encoder reads the
data improperly.
• Encoder malfunctions.
• Servopack defective.
• Turn ON the encoder power
supply again.
Replace the motor if the alarm
occurs frequently.
• Correct the wiring processing
around the encoder.
• Replace the motor if the alarm
occurs frequently.
• Replace the Servopack.
• Servopack defective when used
as incremental encoder.
• Occurs at power ON.
(Pn002.2=1)
Part 5 Chapter 2 Servo System Troubleshooting
Edition 2.6 5-2-8 CP-7 series Mechanical Reference