ACT - Accuracy Check Tool / User Manual 07/2014 Edition
40
4.2.1.1 Intervention Guard
WARNING
To ensure operational safety, all feeder modules must be set up on all tracks. If
insufficient feeder modules are available, an intervention guard ("dummy feeder") must
be set up on unoccupied tracks.
For S tables: 1 track 00116961-xx
6-10 tracks 00116962-xx
11-20 track 00116963-xx
For X tables: 1 track 00141226-xx
If the ACT waffle pack tray is used, the cover plate of the magazine is to be combined
with part "03073250-01 ACT intervention guard, complete" using the knurled screw to
form a single unit (see Figure 4-14
) and is only permitted to be set up in the machine in
this form (Figure 4-15).
Figure 4-13: Component parts of the intervention guard

ACT - Accuracy Check Tool / User Manual 07/2014 Edition
41
Figure 4-14: Intervention guard completely mounted
Figure 4-15: Tray set up with intervention guard
NOTICE
The gaps still remaining to the left and right of the tray must be closed off with the
dummy feeders described above so that full protection against intervention in the
machine from the outside is ensured.

ACT - Accuracy Check Tool / User Manual 07/2014 Edition
42
4.2.2 Inserting the Plate
► Insert the glass plate with the incident light plate (black metal plate) underneath it in the input
section.
NOTICE
The measuring plate needs to be inserted so that the arrows marked on the plate show
in the transport direction.
Figure 4-16: Placing the measuring plate in the conveyor (example SIPLACE X4)
CAUTION
Caution for SX4 and DX4 machines:
The measuring plate needs to be inserted so that the arrows marked on the plate show
against the transport direction on the SX4 and DX4 machines.
Figure 4-17: Placing the measuring plate in the SX4 / DX4 conveyor with the calibration structure (ink spot forward)