00196351-04_UM_ACT_de_en.pdf - 第123页
ACT - Accurac y Check T ool / User Manual 07/2014 Edit ion 49 Figure 4- 26 : Dialog box operating mode switchover to SIPLACE Pro at the station (example SIPLACE D4) ► Press the ST AR T butto n on the mac hine. The ref er…

ACT - Accuracy Check Tool / User Manual 07/2014 Edition
48
Figure 4-24: Dialog box: Access level (example SIPLACE D4)
► Enable the Service access level and confirm your entry with OK.
If a password has been defined, a dialog box will open for you to enter this password.
► Enter the password and confirm with OK.
► Select the menu items Options → Control mode....
Figure 4-25: Basic view of user interface for SC program (example SIPLACE D4)
This opens the Control mode dialog box.
► Select SIPLACE Pro and confirm the setting with OK.

ACT - Accuracy Check Tool / User Manual 07/2014 Edition
49
Figure 4-26: Dialog box operating mode switchover to SIPLACE Pro at the station (example SIPLACE D4)
► Press the START button on the machine.
The reference run is carried out.
► Send the recipe / job to the station with the relevant setup and the ACT placement program.
► From the Options menu, select ACT mode.
The ACT dialog box opens and the machine will automatically switch to Stand Alone mode.
Figure 4-27: Basic view of user interface for SC program (example SIPLACE D4)
After setting ACT mode, an icon will be displayed for ACT.

ACT - Accuracy Check Tool / User Manual 07/2014 Edition
50
Figure 4-28: Dialog box after setting ACT mode. Display: ACT icon
The Enter PCB dialog box is opened (Figure 4-29).
► Select the ACT board.
Figure 4-29: Dialog box: Enter PCB (example SIPLACE D4)
The Enter PCB dialog box is opened (Figure 4-30).
► Select the ACT board.
► Select the conveyor lane.
► Confirm your entry with OK.