00198150-02_SM_TX_en.pdf - 第103页

6 Gantries 6.3 Trailing Cable and Printed Circuit Boards Service Manual SIPLACE TX Series 06/2017 103 Fig.119: Boards on the gantry 1. Vision Head Interface (VHI) 2. Head interface 6.3.6.1 Replacing the X Axis Trailing …

100%1 / 316
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
102 Service Manual SIPLACE TX Series 06/2017
6.3.5 Handling the Hose Unlocking Tool [03047090-xx]
Fig.117: Unlocking Tool for Hoses and Blanking Plugs
Due to the poor access to the pneumatic distributor,
we recommend using the unlocking tool.
With the help of the hose unlocking tool [03047090-xx]
you can open the unlocking ring (blue here) for the
compressed air connection. This enables you to re-
move both the hoses and the blanking plugs (addi-
tional tool "Unlocking tool for QSC-10H" [03051853-
xx]).
Usage
Use the pipe-shaped tool (1) to open the unlocking ring.
Carefully pull the hose or the blanking plug(2) out of the compressed air connection.
6.3.6 Trailing cable
Parts, equipment and tools
Select the applicable trailing cable:
Trailing cable X axis Y axis
Gantry 1 Trailing cable X BG TX G1
[03112678‑xx]
Trailing cable Y TX G1 [03112680‑xx]
Gantry 2 Trailing cable X BG TX G2
[03112674‑xx]
Trailing cable Y TX G2 [03112675‑xx]
See 6.3.6.1 "Replacing the X Axis Trailing
Cable" [}103]
6.3.6.2 "Replacing the Y Axis Trailing
Cable" [}108]
Overview
Fig.118: Trailing cables
1. Boards on the gantry (shown without board cover
here)
2. Pneumatic distributor
3. Trailing cable console (covers)
4. Power track chain
5. Gantry Interface
6. Vision Base interface (VBI) [03115474‑xx]
7. GR X Y distribution SIPLACE TX [03110664‑xx]
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 103
Fig.119: Boards on the gantry
1. Vision Head Interface (VHI)
2. Head interface
6.3.6.1 Replacing the X Axis Trailing Cable
Parts, equipment and tools
Fig.120: Trailing cable
Trailing cable X assembly TX gantry 1
[03112678‑xx]
Trailing cable X assembly TX gantry 2
[03112674‑xx]
Hose unlocking tool [03047090-xx]
Pipe/hose cutters [00381443-xx]
If needed, assembly instructions "Vacuum pump option for SIPLACE TX-Series" [DE
+EN:00198147‑xx]
Loctite 241 [02101037‑xx]
Edding marker, white [00382740-xx]
Help of second person, if needed
Removal
NOTICE
Vacuum pump
When a vacuum pump is fitted, also observe the assembly instructions "SIPLACE TX
Vacuum Pump" [00198147‑xx].
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
104 Service Manual SIPLACE TX Series 06/2017
Fig.121: Disabling the compressed air supply
 CAUTION!
Switch off the compressed air supply.
When working on the pneumatic system, always
switch off the compressed air supply.
.
Push the lever (1) for the compressed air supply
back, until it is positioned horizontally.
Open the screw (2) on the inlet filter to vent the
system. Hold a cloth underneath to capture any
escaping oil.
All pressure gauges must be set to zero.
Dismantling the trailing cable and machine side
Fig.122: Covers
Remove the four screws(1) and remove the
lower cover. These screws are not secured with
Loctite.
Remove the twelve screws(2) and remove the
upper cover. These screws are secured with Loc-
tite241.