00198150-02_SM_TX_en.pdf - 第197页
8 Placement Heads and Stationary Cameras 8.1 Fast Head Exchange Service Manual SIPLACE TX Series 06/2017 197 8 Placement Heads and Stationary Cameras DANGER Observe User Manual ► Please observe the safety instructions in…

7 Conveyor
7.12 Vacuum Tooling
196 Service Manual SIPLACE TX Series 06/2017
7.12 Vacuum Tooling
Spare parts
The following parts can be replaced for vacuum tooling:
●
Basic pack vacuum tooling TX [00588121‑xx]
●
Vacuum suction nozzle, nominal width 2 mm [03136878‑xx]
●
Maintenance unit vacuum tooling TX [03136432‑xx]
●
Valve unit assembly [03138689‑xx]
●
Cable: vacuum tooling [03139108‑xx]
●
Cable: vacuum tooling sensor [03139109‑xx]
●
Vacuum switch VSI V D M8-4 [03118829‑xx]
●
Cable: PCB sensor vacuum tooling 1 [03149630‑xx]
●
Cable: PCB sensor vacuum tooling 2 [03149631‑xx]
Equipment and tools
●
Assembly instructions "Basic pack vacuum tooling SIPLACE TX‑Series" [DE
+EN:00198328‑xx]
Removal / Installation
► For more information about replacing spare parts, please read the assembly instructions.

8 Placement Heads and Stationary Cameras
8.1 Fast Head Exchange
Service Manual SIPLACE TX Series 06/2017 197
8 Placement Heads and Stationary Cameras
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
8.1 Fast Head Exchange
By means of the Fast Head Exchange (FHE) it is possible to replace a placement head within 15
minutes.
NOTICE
CPP/M and C&P20P/M/M2 only
FHE is only possible with CPP and C&P20P/M/M2 heads only. TwinHeads must be calib-
rated manually.
See also
2 Replacing the SIPLACE C&P20 P/M2 Head [}202]
2 Replacing the SIPLACE CPP/M Head [}206]
8.1.1 Preparing the FHE in the Software
Fig.264: Select operator level
► Click the
button to enter the Settings
menu.
► Click the
button to open the Check and set
user settings menu.
► Switch to operator level Machine service or bet-
ter.
Fig.265: Service menu
► Click on Service
button.
► Click the Fast hardware exchange button.

8 Placement Heads and Stationary Cameras
8.1 Fast Head Exchange
198 Service Manual SIPLACE TX Series 06/2017
Fig.266: Fast head exchange
► Highlight the heads to be replaced.
► Click on Prepare for exchange and shut down.
The following actions will be carried out automatically:
●
The current nozzles will be returned and calibra-
tion nozzles will be picked up, if present.
●
A nozzle and height reference run will be carried
out.
●
The machine will be shut down.
In a next step you can dismantle the heads.
8.1.2 Removing and Installing the Placement Head
► For actually removing and installing the placement head hardware, proceed as described in
the relevant chapter.
Replacing the SIPLACE C&P20 P/M2 Head [}202]
Replacing the SIPLACE CPP/M Head [}206]
See also
2 Replacing the SIPLACE C&P20 P/M2 Head [}202]
2 Replacing the SIPLACE CPP/M Head [}206]