00198150-02_SM_TX_en.pdf - 第235页

10 COT Insert 10.3 Replacing the COTi Central Unit and Lifting Mechanics Service Manual SIPLACE TX Series 06/2017 235 10.3 Replacing the COTi Central Unit and Lifting Mechanics NOTICE Working on the COT insert without co…

100%1 / 316
10 COT Insert
10.2 Installation Positions of COT Insert (Table Positions)
234 Service Manual SIPLACE TX Series 06/2017
10.2 Installation Positions of COT Insert (Table Positions)
Fig.312: Installation positions
The inner and outer mounting positions depend on the
machine type.
The following installation positions apply to the
SIPLACE TX-Series:
1. COT insert at inner position:
SIPLACE TX1, TX2: location 2
SIPLACE TX2i: location 1 and 2
2. COT insert at outer position:
SIPLACE TX1, TX2: location 1
Fig.313: Example: inner position
Example:
1. COTi central unit mounted at inner position
10 COT Insert
10.3 Replacing the COTi Central Unit and Lifting Mechanics
Service Manual SIPLACE TX Series 06/2017 235
10.3 Replacing the COTi Central Unit and Lifting Mechanics
NOTICE
Working on the COT insert without complete removal of this
For some tasks on the COT insert, it may be enough to just pull the COT insert slightly out
of the machine. In this case, follow the procedure for replacement but observe the following
instructions:
Remove the screws fastening the central unit and the lifting mechanics.
You don't usually need to disconnect the cable. However, if the cable is too short, un-
plug it.
Slightly pull the COT insert out of the machine.
WARNING
Heavy machine parts
Make sure that the COT insert does not fall out of the machine!
Overview
Fig.314: COTi parts
The COTi for SIPLACE TX machines is split into three
separate parts (units) which are mounted directly to the
machine frame.
These parts are as follows:
1. Lifting mechanics left
2. Lifting mechanics right
3. COTi central unit
The parts are directly fixed with eight screws to the
machine frame (four screws at the COTi central unit and
two screws on each of the lifting mechanics).
For the positions of the COTi in the machine see 10.2 "Installation Positions of COT Insert (Table
Positions)" [}234].
Parts, equipment and tools
Suitable lifting device (e.g. hand-operated crane)
Detailed circuit diagrams folder for SIPLACE TX-Series (up to no. 499) [DE+EN: 00197933-xx]
Detailed circuit diagrams folder for SIPLACE TX-Series (from no. 500) [DE+EN: 00198274-xx]
Fig.315: COTi central unit assembly [03117339‑xx]
(with FCU and tape cutter)
Select the required parts (also see below):
Lifting mechanics left assy [03126040‑xx]
Lifting mechanics right assy [03126039‑xx]
COTi central unit assy [03117339‑xx]
(with FCU and tape cutter)
10 COT Insert
10.3 Replacing the COTi Central Unit and Lifting Mechanics
236 Service Manual SIPLACE TX Series 06/2017
Removal of left and right lifting mechanics
NOTICE
Shown by example
The following procedure is shown by example of the left lifting mechanics. The procedure
for the right lifting mechanics the same. Relevant differences will be mentioned.
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Fig.316: Locking flap
The safety bolt(1) fixes the connection between the
pneumatic cylinder and the lifting mechanics.
Flip the safety catch down.
Remove the safety bolt, to access the connec-
tion.
 CAUTION!
Pay attention to the position and number of
washers used.
.
Fig.317: Removing the lifting mechanics
Dismantle the lifting mechanics by removing the
screws(1).
Fig.318: Lifting mechanics parts
Take out the "left lifting mechanics assem-
bly" [03126040‑xx].