13 Docking Station for Component Trolley 13.1 Docking Station for Component Trolley - Overview Service Manual SIPLACE TX Series 06/2017 287 13 Docking Station for Component Trolley DANGER Observe User Manual ► Please obs…

100%1 / 316
12 SIPLACE TX-Series Component Trolley
12.7 Replacing the Feeder Centering [03028910-xx]
286 Service Manual SIPLACE TX Series 06/2017
13 Docking Station for Component Trolley
13.1 Docking Station for Component Trolley - Overview
Service Manual SIPLACE TX Series 06/2017 287
13 Docking Station for Component Trolley
DANGER
Observe User Manual
Please observe the safety instructions in the user manual for all work!
NOTICE
Retrofit kit for TX-Series
The X-Series docking station can be retrofitted for user with TX-Series component trolleys.
For more details, read the technical information "Conversion kit for TX component trol-
ley docking station" [DE:TI2017‑01D02] [EN:TI2017‑01E02].
13.1 Docking Station for Component Trolley - Overview
3
4
1
7
6
5
4
2
Fig.404: Docking station – overview 1
1. Docking station – assembly [00116933-xx]
2. Unlocking pushbutton [00334095-xx]
13.10 "Replacing the Unlocking Pushbutton
[00334095-xx]" [}296]
3. Power pack and pressure control valve for
locking cylinder (behind the cover)
13.2 "Replacing the Power Pack
[03121806-xx]" [}288]
4. Locking lever [03025104-xx]
13.5 "Replacing the Locking Lever
[03025104-XX]" [}291]
5. Feeder unlocking device 40-fold [03011582-XX]
13.7 "Replacing the 40-Fold Feeder Unlock
Device [03011582-xx]" [}293]
6. Feeder Control Unit (FCU)
13.8 "Replacing the Feeder Control Unit (FCU)
[03059623Sxx]" [}294]
7. Short-stroke cylinder for locking unit
[03034831‑xx]
13.4 "Replacing the Locking Unit Short-Stroke
Cylinder [03034831-xx]" [}290]
1
4
3
2
Fig.405: Docking station – overview 2
1. Control valve [03003489-xx]
13.11 "Replacing the Control Valve [03003489-
xx]" [}297]
2. ON/OFF switch
3. Microfuse [03033387-xx]
13.3 "Replacing the Microfuse [03033387-
xx]" [}289]
4. Pressure control valve for bulkcase feeder and
main connection (5.5 bar)
13.6 "Replacing the Positions End Switch of
the Component Trolley Locking Device
[03033395-xx]" [}292]
13.9 "Replacing the Complete Coupling - Earth-
ing and Compressed Air for the Bulk
Case" [}295]
13 Docking Station for Component Trolley
13.2 Replacing the Power Pack [03121806-xx]
288 Service Manual SIPLACE TX Series 06/2017
13.2 Replacing the Power Pack [03121806-xx]
NOTICE
Observe the technical information
Observe the technical information "Power pack for docking station for component trol-
ley SIPLACE X [116933] and SX [116965] has been discontinued" [DE: TI2015-04D07]
[EN: TI2015-04E07].
Parts, equipment and tools
Switching power supply RSP-500-27 [03121806‑xx] (replaces: [03025938‑xx])
Detailed circuit diagrams folder for SIPLACE TX-Series (up to no. 499) [DE+EN: 00197933-
xx]
Detailed circuit diagrams folder for SIPLACE TX-Series (from no. 500) [DE+EN: 00198274-xx]
Removal / installation
DANGER
Switch off the voltage supply
Press the ON/OFF button to switch off and disconnect the power supply.
4
3
1
3
2
Fig.406: Removing the cover
1. Operation cover
2. Bar for clamping the cover
3. Four fastening screws
4. Power pack
Remove the four screws (3) fastening the cover
(1). The cover is clamped in place with the help
of the bar(2).
Pull the cover out of the docking station.
Take care not to damage the earth connection.
4
3
1
2
Fig.407: Removing the power pack
Disconnect all electrical connections(4) to the
power pack(3). You may want to mark their posi-
tions to make clear assignment easier later on.
Remove the four screws (2) fastening the power
pack on the inside of the docking station.
Connect all cables and fit the new power pack.
Press the ON/OFF button(1) to switch on.
Set the output voltage of the power pack at ter-
minals nine and twelve:
Standard (without BulkFeeder):
26.8 V (+/- 0.5 V)
When using the BulkFeeders the output
voltage is set permanently to
28.0V(+/‑0.5V).
Refit the cover.