6 Gantries 6.4 MHCU, Boards and Camera Service Manual SIPLACE TX Series 06/2017 115 6.4.2.1 X Base Adapter C&P [03045647-xx] This board is used for C&P20x and CPP heads on SIPLACE X-Series S, SX4/DX4 and TX-Serie…

6 Gantries
6.4 MHCU, Boards and Camera
114 Service Manual SIPLACE TX Series 06/2017
Fig.142: Head adapter MHCU (example of C&P20P shown)
► Unplug all electrical connections to the head ad-
apter(1). You may want to mark the position to
make clear assignment easier later on.
Fig.143: Head adapter
► Remove the screws(2) fastening the head ad-
apter.
► In addition, the head adapter is fastened with the
topmost two MHCU screws(1)in each case. Re-
move these two screws as well.
► Carefully pull the head adapter down and off.
The head adapter is connected to the head inter-
face from below via a press-fit connection.
Converting the MHCU
If you have ordered the base adapter without MHCU(s) you will have to convert the MHCU(s). Pro-
ceed as follows:
Fig.144: Head adapter backside
► Remove the two screws(1) fastening the MHCU
on the back of the board and carefully pull the
MHCU off the base adapter.
CAUTION!
Washers
Make sure that you do not lose the washers.
.
CAUTION!
Pins
Make sure that you do not damage the pins un-
der the MHCU.
.
► Only for Twin head: Repeat the procedure for the second MHCU.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
► Check the embedded software and perform a download if needed (see 6.4.11 "eSW
Download (SW 70x)" [}130]).
See also
2 Replacing the SIPLACE CPP/M Head [}206]
2 Replacing the SIPLACE TwinHead [}210]
2 Replacing the SIPLACE C&P20 P/M2 Head [}202]

6 Gantries
6.4 MHCU, Boards and Camera
Service Manual SIPLACE TX Series 06/2017 115
6.4.2.1 X Base Adapter C&P [03045647-xx]
This board is used for C&P20x and CPP heads on SIPLACE X-Series S, SX4/DX4 and TX-Series
machines.
NOTICE
C&P20P
The X base adapter needs at least function level 08 for the C&P20 P head. In this case,
you may need longer flat ribbon cables.
Version 09
Fig.145: X base adapter C&P
Connections [03045647-09]
1, 2 X1-X2 flat ribbon connection for CPP or
C&P20
3 X3 Connection to the head interface
board C700
4, 14,
15
X4, X14, X15 – connector for (M)HCU 5 X5 Test connector for FPGA
6 X6 Programming connector for FPGA 7 X7 Test connector (M)HCU
8 X8 connectors for inlet vacuum sensor
(cable X1a)
H LED H3- H9
S1 Switch S1 intermediate circuit voltage
Z axis
40V C&P20 (switch top)
150V CPP(switch bottom)

6 Gantries
6.4 MHCU, Boards and Camera
116 Service Manual SIPLACE TX Series 06/2017
6.4.2.2 X Base Adapter Twin [03054879-xx]
This board is used for Twin heads on SIPLACE X series S, SX4/DX4 and TX series machines.
From version -03:
Fig.146: X Base Adapter Twin [03054879-03/-04]
X4
X14
X15
Connections for (M)HCU (TwinHead
module2)
X9
X16
X17
Connections for (M)HCU (TwinHead
module1)
X30
X31
Connections for TwinHead module 2 X32
X33
Connections for TwinHead module 1
X3 Connection on the head interface Hx LEDs (see below)
LED [03054879-03]
LED Color Status Signal name Description
H2 GN ON - (M)HCU2 programming connector connected
H3 RD ON FPGA_TEST_6 1.5VDC PowerFail
H4 RD ON FPGA_TEST_2 3.3VDC PowerFail
H5 RD ON FPGA_TEST_4 5VDC PowerFail
H6 RD ON FPGA_TEST_1 15VDC PowerFail
H7 RD ON FPGA_TEST_3 DP PowerFail, not used
H8 RD ON FPGA_TEST_5 24VDC PowerFail
H9 RD ON POWERFAIL_LOCAL PowerFail board:
ON, when 1.5VDC, 3.3VDC, 5VDC and 15VDC
are outside the permissible tolerance