8 Placement Heads and Stationary Cameras
8.6 Stationary Camera
Service Manual SIPLACE TX Series 06/2017 221
8.6.4 PCBs Stationary Cameras
8.6.4.1 Vision LED Controller VLC25/33 GigE DTC [03117981‑xx] [03117587‑xx]
The
Vision LED Controller VLC33 GigE DTC [03117981-xx] and
Vision LED Controller VLC25 GigE DTC [03117587-xx]
boards are identical, except for the connectors X21 and X22. These connectors are only present on
the VLC25 board.
The boards are part of the stationary camera SST25/33 GigE.
Fig.301: Vision LED Controller VLC25 GigE DTC [03117587-xx]
1 CAN bus 2 X4: Cable for power supply
3 X5: Cable for power supply, bridge to
FC camera
(Not used in TX-Series)
4 DIP switch SW1 (see below)
5 Connector X22 (VLC25 only) 6 Connector X21 (VLC25 only)
NOTICE
X21 and X22
The connectors X21 and X22 are not used in TX-Series machines.
8 Placement Heads and Stationary Cameras
8.7 Calibration
222 Service Manual SIPLACE TX Series 06/2017
DIP switch S1 [03117587-xx] [03117981-01]
Switch Status Signal name Description
S1.1 OFF VCU_CODE OFF: normal operation, ON: Reset
Gantry 1 Gantry 2 Gantry 3 Gantry 4
S1.2 ON/OFF PORTAL_ID_0 OFF ON OFF ON
S1.3 ON/OFF GANTRY_ID_1 OFF OFF ON ON
S1.4 OFF SMD_LED OFF: standard LED, ON: SMD LED
S1.5 OFF CAN_H OFF: with CAN terminator
ON: without CAN terminator
S1.6 ON CAN_GROUP ON: IC camera , OFF: FC camera
8.7 Calibration
Overview
With the calibration of the component camera the following values are determined:
the relationship of "camera pixel size to resolution of machine measuring system (X,Y)", the "cam-
era center point in X and Y direction" and the "torsion angle of the CCD sensor in the camera". This
is following by determining the head offset and the segment offsets for the top and bottom.
Head offset: the head offset is the distance between the PCB camera and the nozzle (seg-
ment1). The target is a fixed value (X=0 and Y=‑105mm) to which an offset value (from the
head calibration) is added.
Segment offset top: the top segment offset involves turning the calibration tool in the compo-
nent camera in 0°, 90°, 180° and 270°. The value determined is that of the rotating center of
the nozzle tip in relation to the component camera center in the X and Y direction.
Segment offset bottom: the bottom segment offset involves recording and measuring the
calibration tool in the 0°, 90°, 180° and 270° positions. The value determined is that of the ro-
tating center point of the nozzle tip when the Z axis is extended in relation to the PCB camera.
Segment1 forms the reference (X=0,Y=0) to the other segments.
8 Placement Heads and Stationary Cameras
8.7 Calibration
Service Manual SIPLACE TX Series 06/2017 223
8.7.1 Calibrating the Heads and Cameras (SW70x)
Fig.302: Select operator level
Click the
button to enter the Settings
menu.
Click the
button to open the Check and set
user settings menu.
Switch to operator level Machine service or bet-
ter.
Fig.303: Service Menu
Click the
button to enter the Service menu.
Click the Automatic calibration button.
Fig.304: Automatic Calibration
Select Heads and cameras.
Click on the Continue button.
Follow the instructions on the next pages:
On the next page, select the gantries on which
the heads to be calibrated are located and then
click on the Next button.
The next step is to check the calibration condi-
tions (nozzle, calibration tool etc.). Follow the in-
structions provided.
After this step, calibration will begin. All required inter-
mediate steps (head height etc.) will be performed
automatically.