00198150-02_SM_TX_en.pdf - 第269页
11 Cutter 11.9 Replacing the Cutter Blades Service Manual SIPLACE TX Series 06/2017 269 Final work 1 2 Fig.376: Cutter (using example of X-Series) ► Use a feeler gauge to check the gap between the tape deflector (1) and…

11 Cutter
11.9 Replacing the Cutter Blades
268 Service Manual SIPLACE TX Series 06/2017
► Fit the two caps over the fastening screws on the movable blade.
► Place the two new spacers (4) to the left and right of the moveable blade. The spacer side
marked with a number must face away from the blade.
CAUTION
The spacers and blades are matched!
► Do not use any spacers from other sets of blades.
► Lubricate the contact/slide surfaces for the moveable blade, as described in the section "Pre-
parations".
CAUTION
Only apply grease to the exact points required!
The overlapping cutting surfaces may only be greased with Interflon Fin grease
[03020782-xx]. Also observe the preventive maintenance manual for your machine.
1
2
4
1
5
4
3
2
Fig.375: Cutter
► Place a shim (0.5 - 1.0 mm thickness) on the left
and right, between the spacer and the front of the
movable blade (1).
► Place the previously removed holding-down
device (2) onto the new spacers.
NOTICE!
Holding-down device
The holding-down devices with version 03 are
those designed for cutters with version 04 (=
with tape deflector)
.
► Insert the dismantled wiper unit (3) and the holding-down devices and tighten loosely with the
four hexagon socket-head screws (4).
► Push the spacers (with inserted feeler gauges) as far as possible in the direction of the move-
able blade. The maximum permissible gap is 1.0 mm.
► Now tighten the four screws (4) crosswise at the holding-down device.
► Remove the two feeler gauges.
► Insert the new stationary blade (5) in the correct position and screw tight.

11 Cutter
11.9 Replacing the Cutter Blades
Service Manual SIPLACE TX Series 06/2017 269
Final work
1
2
Fig.376: Cutter (using example of X-Series)
► Use a feeler gauge to check the gap between the
tape deflector (1) and the moveable blade (2),
along the entire length and width of the blade.
ð The 0.05 mm feeler gauge should fit through
the gap.
ð The 0.25 mm feeler gauge should not fit
through the gap.
If the gap is not correct, check:
●
Whether the wrong holding-down device has
been installed (with function level < 03).
●
The holding-down devices are those designed for
cutters with function status -04 (= with tape de-
flector).
●
Whether the blades, tape deflector etc. were
cleaned before installation.
If the gap is correct:
► Fit the baffle plate and cover plate. Make sure that the edges are parallel.
CAUTION
Check how the cables are run!
Make sure that the cables and hoses are not pinched or subjected to excess strain.
► Remove the clamps from the cutter/remove the cutter from the assembly plate.
► Further installation is performed by following the above instructions in the reverse order.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]

11 Cutter
11.10 Replacing Wiper [03000491-xx]
270 Service Manual SIPLACE TX Series 06/2017
11.10 Replacing Wiper [03000491-xx]
Parts, equipment and tools
Fig.377: Wiper
1. Wiper (cutter HF) [03000491‑xx]
Overview
Fig.378: Wiper on cutter
1. Wiper
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Fig.379: Cover plate
► Remove the screws(2) fastening the top cover
plate(1) and then remove the top cover plate.