3 SMPS 3.9 Replacing the Distribution and Fusing Assembly Service Manual SIPLACE TX Series 06/2017 55 3.9 Replacing the Distribution and Fusing Assembly Parts, equipment and tools ● Distribution and fusing board assembly…

100%1 / 316
3 SMPS
3.8 Replacing the AC/DC Converter
54 Service Manual SIPLACE TX Series 06/2017
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the power supply fastening screw and pull out the power supply. For more informa-
tion about this read section 3.2 "Pulling out the Power Supply" [}35].
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4 "Checking For Ab-
sence of Voltage" [}37].
Unplug all electrical connections from the AC/DC converter. Mark their positions to make clear
assignment easier later on.
Push the unlock handle and tilt this slightly upwards. Now take the AC/DC converter up and
off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
Fig.52: Setting screw
Setting the voltage:
Open the protective cap on the setting screw(1).
Use a slotted screwdriver to set the correct
voltage on the AC/DC converter.
Check the voltage with a suitable voltage meas-
uring device between the terminals + and.
3 SMPS
3.9 Replacing the Distribution and Fusing Assembly
Service Manual SIPLACE TX Series 06/2017 55
3.9 Replacing the Distribution and Fusing Assembly
Parts, equipment and tools
Distribution and fusing board assembly TX [03121508‑xx]
Overview
Fig.53: Distribution and fusing board assembly
1. Distribution and fusing board assembly TX
See also the board description: 3.9.1 "Distribution and
Fusing Assembly [03121508-xx]" [}56]
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
DANGER
Checking for absence of voltage!
Before you start working check the power supply for absence of voltage and observe
the waiting times! For more information about this read section 3.4 "Checking For Ab-
sence of Voltage" [}37].
Fig.54: Fastening screws
Unplug all electrical connections to the board.
You might like to mark their positions to make
clear assignment easier later on.
Remove the fastening screws on the board and
the earth conductor.
Remove the board.
Installation
Follow the removal instructions in reverse order for installation.
3 SMPS
3.9 Replacing the Distribution and Fusing Assembly
56 Service Manual SIPLACE TX Series 06/2017
3.9.1 Distribution and Fusing Assembly [03121508-xx]
Fig.55: Distribution and Fusing Assembly [03121508‑xx]
Fuses
Fuse 5x20mm T6,3A 400VDC [03133256‑xx]
Micro fuse 5x20 / T 10A / ceramic [03010627‑xx]
Fuse F10 "power fail signal":
Check functionality with LED D24 (on the right side of XB8A).
While the machine is running the LED D24 is on and the power fail functions of the subsys-
tems are active.
The fuse voltage can be checked at connector X26, pin 2 (24V).
If fuse F10 is blown replace the board "distribution and fusing assembly" [03121508‑xx].
Fuse F13 "internal electronic and diagnostics":
Check functionality with LED D2 (above X8).
If fuse F13 is blown replace the board "distribution and fusing assembly" [03121508‑xx].
NOTICE
F13
The fuse may be removed from the fuse holder, but in most cases the holder is broken after
this.