00198150-02_SM_TX_en.pdf - 第258页

11 Cutter 11.6 Replacing the Protective Guard [03019894-xx] 258 Service Manual SIPLACE TX Series 06/2017 11.6 Replacing the Protective Guard [03019894-xx] Parts, equipment and tools ● Protective guard [03019894-xx] Overv…

100%1 / 316
11 Cutter
11.5 Replacing the Baffle Plate [03019896-xx]
Service Manual SIPLACE TX Series 06/2017 257
11.5 Replacing the Baffle Plate [03019896-xx]
Parts, equipment and tools
Baffle plate [03019896-xx]
Overview
Fig.355: Cutter
1. Baffle plate [03019896-xx]
2. Two fastening screws
3. Clip, connecting baffle plate and protective guard
 CAUTION!
Risk of injury
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Straighten the two clips with pliers.
Remove the two screws fastening the baffle plate.
Remove the baffle plate unit from the cutter.
Installation
Follow the removal instructions in reverse order for installation.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]
11 Cutter
11.6 Replacing the Protective Guard [03019894-xx]
258 Service Manual SIPLACE TX Series 06/2017
11.6 Replacing the Protective Guard [03019894-xx]
Parts, equipment and tools
Protective guard [03019894-xx]
Overview
Fig.356: Protective guard on cutter
1. Protective guard [03019894-xx]
2. Five fastening screws
3. Clip connecting baffle plate and protective guard
 CAUTION!
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Remove the five screws fastening the protective guard.
Straighten the two clips with pliers.
Remove the protective guard from the cutter.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
Fig.357: Fitting the protective guard
Make sure that the five fastening screws are
completely countersunk. The screws must be
flush with the protective guard.
Ensure that there is a gap between the cutter
blade and the edge of the baffle plate inside(1).
If everything is correct, there should be a contact
at position(2).
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]
11 Cutter
11.7 Replacing the Articulated Joint on the Short-Stroke Cylinder [03000518-xx]
Service Manual SIPLACE TX Series 06/2017 259
11.7 Replacing the Articulated Joint on the Short-Stroke
Cylinder [03000518-xx]
Parts, equipment and tools
Articulated joint on the short-stroke cylinder [03000518-xx]
2x hexagon socket fillister head screws ISO4762-M5x35-12.9, geomet. 321+VL [03057290-
xx] (screws for movable blade)
Torque wrench 2.5 - 25 Nm [00376625-xx]
Klüber BEM 34-132 lubricant grease, 1 kg tin [00374565-xx]
Loctite 243 [00334892‑xx]
Removing the articulated joint
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Fig.358: Cover plate
Remove the screws(2) fastening the top cover
plate(1) and then remove the top cover plate.
Fig.359: Baffle plate
Remove the two screws(1) at the front side and
five screws(2) at the inner side fastening the
baffle plate.
Remove the baffle plate unit from the cutter.