3 SMPS
3.4 Checking For Absence of Voltage
Service Manual SIPLACE TX Series 06/2017 39
Procedure for determining absence of voltage
Ensure correct handling of the voltage tester:
The measuring device may only be touched by the insulated test handles (up to inside
handles) and the test electrodes (testing tips) may not be touched!
Fig.26: Correct and incorrect handling of the voltage tester
Determining voltage tester functionality
Fig.27: Performing a self-test of the voltage tester
First perform a self-test of the voltage tester.
Touch the two testing tips together.
The voltage tester will be checked for through-
put and the LED throughput display must be vis-
ible and an audio signal must be heard.
After approx. three seconds you can disconnect
the two testing tips again.
3 SMPS
3.4 Checking For Absence of Voltage
40 Service Manual SIPLACE TX Series 06/2017
Measurement with known reference voltage
To conclude the self-test, check the voltage tester with a known reference voltage.
You can use the service socket on the power supplier (disabled with "110V option") or any other
electrical socket.
Measure the voltage present between the pins and at PE (ground).
Fig.28: Test with reference voltage
Measuring the voltage absence directly after switching machine off
When the machine has been switched off, the full voltage is still present at the measurement points
X303 (in) and X304 (out).
Measurement is always performed at the reference point X305 (GND)!
Pull the power supply out towards the front (see 3.2 "Pulling out the Power Supply" [}35]).
Fig.29: Measuring points
1. Measuring points at power supply
Test 300V IN_X303-X305:
Currently present voltage
Test 300V OUT_X304-X305:
LED display Output 1 at AC/DC converter
Green: Voltage over 220V
The power pack shows an LED display for out-
put 1 > 220 V in green, which means that the
voltage is still over 220 V!
3 SMPS
3.4 Checking For Absence of Voltage
Service Manual SIPLACE TX Series 06/2017 41
The following figure explains the LED status of the PS1 power pack (300 VDC):
Fig.30: LED status PS1-PS2 300VDC
Monitoring the voltage absence after switch-off
The voltage at the measurement points X303 (IN PS1/PS2) and X304 (OUT CAP) only discharges
slowly.
After switch-off, the voltage drops from 300VDC to under 5VDC in approx. five minutes.
Fig.31: Measuring voltage
As soon as the voltage has undershot a value of 220VDC, the LED display on the power pack
changes!