SmartSM手册.pdf - 第28页

SM 400 Us e r 's M anual 画 面 导 言 画 面 导 言 [ 应用 ] 庚 甮 稑 底 ﹢ U t i l it y ﹣ 菢 卛 男 P r in t ﹢ 扙 卶 ﹣ ﹦ P ro d u c t io n I n fo r m a t i on ﹢ 甥 亭 俧 恵 ﹣ ﹦ C o p y B e t w e en P C B Fi l e s ﹢ P C B 斍 仼 乑 闺 皊 拽 责 ﹣ ﹦ F i…

100%1 / 320
SM400 User's Manual
[系统设定(System)]
C al ibrat io n(Sys te m C al ibrat io n(Sys te m S et up) S et up )
设置状态如果被非指定的操作人员改变可能会损伤设备或引起人员受伤。除了被指定的操作人员以外的其他人员绝不可以
任意改变设备设置状态。
寿寿寿
头 (Head))
Head
传送装置 (Conveyor)
Conveyor
位置 (Position)
Dump box
照像机 (Camera)
Camera
外围设备 (Peripherals)
Dump BoxTray Feeder
校正 (Calibration)
设备全体执行校正。
参考 (Preference)
设定设备的运用必要的诸项选项。
装置 (Device)
, ,
SM400 User's Manual
[应用]
UtilityPrintProduction Information Copy Between PCB Files PCB
File Manager Bypass, Warmup 6
寿寿寿
打印 (Print)
PCB宿
生产数据 (Production
Info.)
拷贝 (Copy)
PCBPCB
文件管理 (File Manager)
MMIRenameClear
直通 (ByPass)
(Conveyor)PCB
预热 (Warm Up)
SM400 User's ManualSM400 User's Manual
Overview
Common Align Data
Provides details concerning the align data commonly applied to all parts.
Menu Items
<Camera No.> Select the camera to recognize the component. Available cameras are as follows.
Fly 1 Cam: Fly Camera for Head1.
Fly 2 Cam: Fly Camera for Head2.
Fly 3 Cam: Fly Camera for Head3.
Fly 4 Cam: Fly Camera for Head4.
Fly 5 Cam: Fly Camera for Head5.
Fly 6 Cam: Fly Camera for Head6.
Fix 1 Cam: Fix Camera1. (If Fix Camera1 is installed)
Fix 2 Cam: Fix Camera2. (If Fix Camera2 is installed)
<Light Control> Sets the lighting for the camera to recognize the component.
<Size>
<Align Z> Set the height for recognition. Based on the component surface, if the top is to be
recognized, set - value, and if the bottom is to be recognized, set + value.
<Threshold>
The image viewed through the SM Vision window is composed of each pixel.
Each pixel has a unique value between 0 and 255 according to the seen degree
of brightness. Here, ‘Threshold Value’ indicates the border value deciding
whether each pixel should be recognized in white or black.
<Auto> Check this box to set the <Threshold> value automatically.
<Tolerance H[+]> Set the highest tolerance with a percentage for component recognition.
<Tolerance L[-]>
Set the lowest tolerance with a percentage for component recognition.
<Area Margin>
When the part was picked up, in normal cases, the center of the picked part
must be within the AreaMargin ‘0’ area.
However, when the part can be placed normally by correcting the extent of
deviation even though the center of the picked part was out of the AreaMargin
‘0’ area due to other external cause, the corresponding part can be placed
normally if the deviated center of the part is included in this area by
enlarging the area that checks the part center based on the center of the
mechanism. Generally, set this value to 0~6.