4OM-1208-011_w.pdf - 第111页

1-54 AIVEMT -ID (6) Use the inner holes of the cut unit fi xing jig with the tape clamp being closed and attach the jig with the bent portion being directed upward. Fig. 4A52 W A R N I N G Pay close attention to the cutte…

100%1 / 237
1-53
AIVEMT-ID
4.4 Procedure of Flat Ring Replacement
Time of Replacement
It is recommended that they should be replaced every 3 months (approx.).
Replacement Procedure
(1) Zero the cutter.
Reference
Refer to "4.4 "CUTTER ADJ" Window" in "Chapter 4 (Vol. 2)" for the
zeroing operation of the cutter.
(2) Move down the feeder base and detach the bank feeder change cart.
(3) Turn off the power to the machine.
(4) Open the cover.
(5) Detach the transparent cover (origin and motor sides) and the tape
guide.
Notice
(a) Carefully detach or attach the tape guide to avoid the Y-axis
linear scale being scratched.
(b) When the cutter is not located at its origin, the tape guide
cannot be detached because the fluorine sheet is caught by the
tape clamp.
Tape Guide
Transparent Cover
(Motor Side)
Transparent Cover
(Origin Side)
Fig. 4A51
0606-009
4.4 Procedure of Flat Ring Replacement
1-54
AIVEMT-ID
(6) Use the inner holes of the cut unit fixing jig with the tape clamp being
closed and attach the jig with the bent portion being directed upward.
Fig. 4A52
WARNING
Pay close attention to the cutter blade during the maintenance
work.
Lack of attention will result in a hand injury, etc.
Be sure to attach the fixing jig to the cut unit during the
maintenance work for safety purposes.
(7)
Cut the used flat ring with a cutter on market and detach it.
(8) Attach the flat ring to the flat ring replacement jig.
Fig. 4A53
0606-009
4.4 Procedure of Flat Ring Replacement
1-55
AIVEMT-ID
(9) Put the flat ring replacement jig on the roller on the oscillating side
(outside of the machine).
Push only the flat ring downward by hand and insert it into the groove
of the roller.
Flat Ring
Fig. 4A54
(10) Pay attention to the cutter blade and detach the flat ring replacement
jig.
(11) Attach the tape guide and the transparent cover.
0606-009
4.4 Procedure of Flat Ring Replacement