4-20 AIVEMT -ID Recognition Error ID Description of Recognition Error , Cause, and Remedy (3) Manipulate the image movement buttons on the window until the actual fiducial mark comes over to the fiducial mark template loca…

4-19
AIVEMT-ID
3.5 PEC Recognition Errors
Z
A
B CC DDD
Detailed Classification: Detailed Classification
Small Classification: Small Classification
Middle Classification
0: PEC Recognition (Mark Missing)
1: PEC Recognition (Coarse Recognition Error)
2: PEC Recognition (Detailed Recognition Error)
3: PEC Recognition (Shape Error)
8: PEC Recognition (Inspection Error)
E: PEC Recognition (Other Errors)
Large Classification (6)
Classification Criteria
Notice
When an error ID other than the described ones is issued, contact
our service personnel for some advice.
Table 4D8
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 6 0 ** 001 Specified mark not found in recognizable range.
0 6 1 ** 001 Specified mark not found in recognizable range.
0 6 2 ** 001 Specified mark not found in recognizable range.
(Cause) The fiducial mark and the fiducial mark coordinates X and Y or
the mark data are not suitable.
(Remedy)
Follow the steps below to reset the machine to the normal
condition.
(1) When the [RETURN] button is pressed, the "Manual Alignment
Operation Guide" window appears.
(2) When the [Mnl Align] button is pressed, the following recognition
window appears.
Template of Fiducial Mark
Actual Fiducial Mark
Crosshair
Fig. 4D2 Sample Display of Recognition Window
(Continued to the next page.)
0606-009
3.5 PEC Recognition Errors

4-20
AIVEMT-ID
Recognition Error ID Description of Recognition Error, Cause, and Remedy
(3) Manipulate the image movement buttons on the window until the actual
fiducial mark comes over to the fiducial mark template located at the
center of the crosshair.
Enlarge the view for accurate alignment operation. Otherwise,
components may not placed accurately.
(4) After the actual fiducial mark has come over to the fiducial mark
template, press the position definition button. The "AUTO OPN."
window resumes.
(5) When the [START] button on the operation panel is pressed, the
automatic operation restarts.
Notice
When the [x] button is pressed to exit from the recognition window,
the "Manual Alignment Operation Guide" window resumes.
Position Definition
Button
Image Movement
Buttons
Fig. 4D3 Operation Buttons
0 6 2 * * 1 * * Edge not detected.
(Cause) PCB Recognition Error
(Remedy) Contact our service personnel for details.
0 6
3 ** 101 Specified mark is not circle.
0 6 3 ** 102 Specified mark is not square.
0 6 3 ** 201 Edge not detected.
(Cause) PCB Recognition Error
(Remedy) Contact our service personnel for details.
0 6
8 ** 101 Specified mark not found in recognizable range.
0 6 8 ** 102 Specified mark not found in recognizable range.
0 6 8 ** 201 Extensive error in similitude of mark size
0 6 8
** 202 Extensive error in similitude of mark size
0 6 8
** 301 Extensive error in similitude of mark shape
0 6 8
** 302 Extensive error in similitude of mark shape
0 6 8
** 401 Extensive error in similitude of mark shape
0 6 8
** 402 Extensive error in similitude of mark shape
0 6 8
** 501 Specified mark not found in recognizable range.
0 6 8 ** 502 Specified mark not found in recognizable range.
0 6 8 ** 601 Specified mark not found in recognizable range.
0 6 8 ** 602 Specified mark not found in recognizable range.
0 6 8 ** 603 Specified mark not found in recognizable range.
0 6 8 ** 604 Specified mark not found in recognizable range.
(Cause) PCB Recognition Error
(Remedy) Contact our service personnel for details.
0606-009
3.5 PEC Recognition Errors

4-21
AIVEMT-ID
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 6 E ** 001 Others
(Cause) Self-Diagnostics Error Message
(Remedy) Contact our service personnel for details.
1 6
* * * * * * Others
(Cause) Self-Diagnostics Error Message
(Remedy) Contact our service personnel for details.
0606-009
3.5 PEC Recognition Errors