4OM-1208-011_w.pdf - 第153页
3-4 AIVEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 400303 B Beam Power Shutoff ----- 400401 Interlock Error The [emergency stop] switch was pressed. ----- 400402 Interlock Error Safety cover opened Please…

3-3
AIVEMT-ID
3. Error IDs and Remedial Procedures
3.1 Safety Devices
Table 4C3
Erroe ID Error Name, Description, Cause, and Remedy
400101 Load Power Shutoff
The [emergency stop] switch was pressed.
-----
400102 Load Power Shutoff
The air pressure is too low.
-----
400103 Load Power Shutoff
Circuit protector is active.
-----
400104 Load Power Shutoff
-----
400105 Load Power Shutoff
Load Power is OFF
Please check the safety relay (K15) wiring.
400106 Load Power Shutoff
-----
400107 Load Power Shutoff
Load power-on timeout.
-----
400108 Load Power Shutoff
-----
400201 Beam Power Shutoff
-----
400202 Beam Power Shutoff
Load power-on timeout.
-----
400203 Beam Power Shutoff
-----
400301 B Beam Power Shutoff
-----
400302 B Beam Power Shutoff
-----
0606-009
3. Error IDs and Remedial Procedures

3-4
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
400303 B Beam Power Shutoff
-----
400401 Interlock Error
The [emergency stop] switch was pressed.
-----
400402 Interlock Error
Safety cover opened
Please shut a safety cover and push the [POWER ON] button.
400403 Interlock Error
Safety cover(CV) detected
-----
400404 Interlock Error
Beam XY(Raer) main power off
-----
400405 Interlock Error
Beam XY(front) main power off
-----
400406 Interlock Error
Head (Rear) Nozzle downward detected
The starting point must return.
400407 Interlock Error
Head (Front) Nozzle downward detected
The starting point must return.
400408 Interlock Error
Disengaged Latch (Rear) was detected.
-----
400409 Interlock Error
Disengaged Latch (Front) was detected.
-----
40040a Interlock Error
The suppressor Mis-set (Rear) detected.
Please execute the Warm start.
40040b Interlock Error
The suppressor Mis-set (front) detected.
Please execute the Warm start.
40040c Interlock Error
Component Mis-Pickup(rear) detected
Please remove the factor which is shading the feeder peristome sensor (rear), and
carry out a zero return. (It continues at a warm start)
40040d Interlock Error
Component Mis-Pickup(front) detected
Please remove the factor which is shading the feeder peristome sensor (front), and
carry out a zero return. (It continues at a warm start)
0606-009
3.1 Safety Devices

3-5
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
40040e Interlock Error
CB Alarm XY(Rear) Detected
-----
40040f Interlock Error
CB Alarm XY(Front) Detected
-----
400410 Interlock Error
CB Error (Conveyor/Wutter) Detected
-----
400411 Interlock Error
CB Alarm (CPU2) Detected
-----
400412 Interlock Error
CB Alarm (DC24) Detected
-----
400413 Interlock Error
Air pressure Drop detected
-----
400414 Interlock Error
CB Alarm (Vacuum Pump)
-----
400415 Interlock Error
The urgent stop reserve input was input.
Turning on the power supply again then the emergency stop must be pushed, and
the starting point must return later.
400416 Interlock Error
NL axis (Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
The starting point must return.
400417 Interlock Error
NL axis(Rear) Interlock Detected. Please confi
rm the nozzle has not fallen when
you push the beam by the hand.
The starting point must return.
400418 Interlock Error
L1 axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400419
Interlock Error
L2 axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400420 Interlock Error
L3 axis (Front) Interlock Detected. Please confi
rm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
0606-009
3.1 Safety Devices