4OM-1208-011_w.pdf - 第237页
Copying Prohibited 1st Edition Issued Jan., 2004 1 1th Edition Issued Sep., 2009 Compiled and Distributed by 0909-01 1 AIVEMT -ID 6, Menuma-nishi 1-chome, Kumagaya-shi, Saitama 360-0238, Japan TEL : +81-48-506-6086 F AX …

5-14
AIVEMT-ID
(3) Positional and Angular Deviations of Component Placement
END
OK
OK
OK
OK
OK
OK
NG
NG
NG
NG
NG
NG
START
Dirt,Magnetization,
and/or Electrification on
Vacuum Nozzle
Cleaning,
Demagnetization,
and/or Deelectrification
Clogged Hole of
Vacuum Nozzle
Adjustment
Verification of PCB
Thickness Data
Correction
Component
Library Data
Confirmation of
Component Shape
Correction
Check Item 3.1.
Air Joint Disconnected
Replacement or Repair
Positional Deviation
Angular Deviation
Fig. 4E12
3.2 Symptom-Based Troubleshooting
0606-009

5-15
AIVEMT-ID
0606-009

Copying Prohibited
1st Edition Issued Jan., 2004
11th Edition Issued Sep., 2009
Compiled and Distributed by
0909-011
AIVEMT-ID
6, Menuma-nishi 1-chome, Kumagaya-shi, Saitama 360-0238, Japan
TEL : +81-48-506-6086 FAX : +81-48-567-0084