3-14 AIVEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 422101 Cnvr . Positioning 1 Overtime PCB from inp. buffer Cnvr . was not received. Please continue the work after checking the PCB on a conveyor . 42210…

100%1 / 237
3-13
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
421301 Input Buffer Cnvr. Error
The carrying in operation was not able to begin.
-----
421302 Input Buffer Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
421303 Input Buffer Cnvr. Error
The exhaust operation was not able to begin.
-----
421304 Input Buffer Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
421305 Input Buffer Cnvr. Error
The PCB transport to receiving position was not able to begin.
-----
421306 Input Buffer Cnvr. Error
The error was detected while transporting to the receiving position.
-----
421307 Input Buffer Cnvr. Error
The operation moving to the arrangement position was not able to begin.
-----
421308 Input Buffer Cnvr. Error
The error was detected while transporting to the arrangement position.
-----
421309 Input Buffer Cnvr. Error
The input machine work transfer signal was turned off before the completion of PCB
carrying-in operation.
Please continue the work after checking the PCB on a conveyor.
421310 Input Buffer Cnvr. Error
The reversal positioning operation was not able to begin.
-----
421311 Input Buffer Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
0606-009
3.3 Conveyor
3-14
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
422101 Cnvr. Positioning 1 Overtime
PCB from inp. buffer Cnvr. was not received.
Please continue the work after checking the PCB on a conveyor.
422102
Cnvr. Positioning 1 Overtime
PCB moving to inp. Buffer cnvr. was not received.
Please continue the work after checking the PCB on a conveyor.
422103
Cnvr. Positioning 1 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
422104 Cnvr. Positioning 1 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
422106 Cnvr. Positioning 1 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
422107 Cnvr. Positioning 1 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
422201 Cnvr. Positioning 1 PCB Detection
PCB’s were at inlet and outlet of cnvr
.
Please continue the work after checking the PCB on a conveyor.
422202
Cnvr. Positioning 1 PCB Detection
There is no PCB on the conveyer. After the PCB carrying is ended, it can not be
detected.
Please continue the work after checking the PCB on a conveyor.
422203
Cnvr. Positioning 1 PCB Detection
No PCB on the cnvr. After positioning released, PCB could not be detected.
Please continue the work after checking the PCB on a conveyor.
422204
Cnvr. Positioning 1 PCB Detection
The conveyer entrance sensor detected PCB.
Please continue the work after checking the PCB on a conveyor.
0606-009
3.3 Conveyor
3-15
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
422301 Cnvr. Positioning 1 Error
The carrying in operation was not able to begin.
-----
422302 Cnvr. Positioning 1 Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
422303 Cnvr. Positioning 1 Error
The exhaust operation was not able to begin.
-----
422304 Cnvr. Positioning 1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
422305 Cnvr. Positioning 1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning 1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning 1 Error
Rise operation of a PCB locate stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning 1 Error
Downward operation of a PCB locate stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning 1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning 1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the PCB on a conveyor.
422311 Cnvr. Positioning 1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning 1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
0606-009