4-16 AIVEMT -ID Recognition Error ID Description of Recognition Error , Cause, and Remedy 0 5 1 * * 6 0 1 Shape (L type) cannot be detected 0 5 1 * * 6 0 2 Shape (U type) cannot be detected. 0 5 1 * * 6 0 3 Shape (edge) …

4-15
AIVEMT-ID
3.4 Component Recognition Errors
Z
A
B CC DDD
Detailed Classification: Detailed Classification
Small Classification: Small Classification
Middle Classification
0: Component Recognition (Component Missing)
1: Component Recognition (Coarse Recognition Error)
2: Component Recognition (Detailed Recognition Error)
8: Component Recognition (Inspection Error)
9: Component Recognition (Judgment Error)
A: Component Recognition (Judgment Error)
E: Component Recognition (Other Errors)
Large Classification (5)
Classification Criteria
Notice
When an error ID other than the described ones is issued, contact
our service personnel for some advice.
Table 4D7
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 5 0 ** 001 Component was not found.
(Cause 1) Check if the feeder is loaded with components other than the
specified ones (the components to be used).
(Cause 2) The vacuum suction force is too weak.
(Cause 3) An
improper nozzle is selected for the components or vice versa.
(Remedy 1) Check if proper components are used.
(Remedy 2) Check the vacuum pressure.
(Remedy 3) Check the parameters in the nozzle type data and the
component library data.
0 5 1
** 001 Component was not detected.
0 5 1
** 101 The detection window of the length position of lead sequence can't be set
up.
0 5 1
** 102 The length position of a lead sequence can't be detected.
0 5 1
** 103 Impossible to set the window for lead detection at the corner.
0 5 1 ** 104 The lead edge of a corner can't be detected.
0 5 1
** 105 The lead of a corner can't be detected.
0 5 1
** 106 Few lead numbers of the detected corner than the setup.
0 5 1
** 107 The distance during the lead of the detected corner is poor.
0 5 1 ** 108 The angle during the lead of the detected corner is poor.
0 5 1 ** 201 No Electrode (ball) Detected.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0606-009
3.4 Component Recognition Errors

4-16
AIVEMT-ID
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 5 1 ** 601 Shape (L type) cannot be detected
0 5 1 ** 602 Shape (U type) cannot be detected.
0 5 1
** 603 Shape (edge) cannot be detected.
0 5 1
** 604 Shape (rectangle) cannot be detected.
0 5 1
** 605 Shape (oval) cannot be detected.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0 5
2 ** 101 More than two corners of a component are hidden by the protruded nozzle.
0
5 2
** 102 Corner not detected.
0 5 2
** 201 Some edges cannot be detected because they are hidden by the nozzle.
0 5 2
** 202 Edge not detected.
0 5 2
** 203 Some edges cannot be detected because they are hidden by the nozzle.
0 5 2
** 204 Edge not detected.
0 5 2
** 301 Angle calculation impossible.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0 5
2 ** 401 Impossible to set the window for lead detection.
0
5 2
** 402 The length position of a lead can't be set up.
0 5 2
** 403 The detected number of leads is smaller than the set value.
0 5 2
** 404 The detected number of leads is larger than the set value.
(Cause) The results of the lead inspection differ from the parameters
specified in the component library data for the selected
components.
(Remedy) Check the leads of the selected component and the component
library data.
Correct wrong parameters if they are set in the component
library data.
0 5 2
** 501 Electrode(ball) which is in agreement with data was undetectable.
0 5 2
** 502
Since a sufficient number of Electrode(ball) were undetectable, it cannot
position.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0 5
2 ** 601 Shape (L type) cannot be detected.
0 5 2 ** 602 Shape (U type) cannot be detected.
0 5 2
** 603 Shape (edge) cannot be detected.
0 5 2
** 604 Shape (rectangle) cannot be detected.
0 5 2
** 605 Shape (oval) cannot be detected.
0 5 2
** 606 There is shape that cannot be detected as in the shade of nozzle etc.
0 5 2
** 607 The Shape corresponding to data was not able to be detected.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0606-009
3.4 Component Recognition Errors

4-17
AIVEMT-ID
Recognition Error ID Description of Recognition Error, Cause, and Remedy
0 5 8 ** 001 The pick-up position has deviated greatly.
0 5 8 ** 002 The pick-up position has deviated greatly in X direction.
0 5 8
** 003 The pick-up position has deviated greatly in Y direction.
0 5 8 ** 004 The pick angular skew is big.
(Cause) Component Recognition Error
(Remedy) Contact our service personnel for details.
0 5
8 ** 101 Component outward length X is incorrect.
0
5 8
** 102 Component outward length X is shorter than the tolerance.
0 5 8
** 103 Component outward length X is longer than the tolerance.
0 5 8
** 104 Component outward length Y is incorrect.
0 5 8 ** 105 Component outward length Y is shorter than the tolerance.
0 5 8 ** 106 Component outward length Y is longer than the tolerance.
0 5 8 ** 107 Component outward length X or Y is incorrect.
0 5 8 ** 108 Component outward length X or Y is shorter than the tolerance.
0 5 8 ** 109 Component outward length X or Y is longer than the tolerance.
(Cause 1) Wrong parameters are set in the "X [mm]" and "Y [mm]" text
boxes of "Mold size" and the "Mold size tolerance X [mm]"
and "Mold size tolerance Y [mm]" text boxes for the selected
components.
X
Y
Fig. 4D1
(Remedy 1) Check the selected components and the parameters set in the
"X [mm]" and "Y [mm]" text boxes of "Mold size" and the "Mold
size tolerance X [mm]" and "Mold size tolerance Y [mm]" text
boxes for the selected components in the component library
data.
Correct wrong parameters if they are set in the component
library data.
0606-009
3.4 Component Recognition Errors