4OM-1208-011_w.pdf - 第178页

3-27 AIVEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 49070e Nozzle set up The remains nozzle was detected on the head. The nozzle cannot be set to this position. Please confirm the nozzle has not adhered to…

100%1 / 237
3-26
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set up
Nozzle Stocker up/dowon failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490705 Nozzle set up
Nozzle existence confirmation has error.
Please check whether there is any dif
ference in stocker arrangement data and real
arrangement.
490706 Nozzle set up
Head nozzle existence confi
rmation has error.
Please check whether there is any difference in head arrangement data and real
arrangement.
490707 Nozzle set up
There is no free space for nozzle storing.
Please confi
rm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufficient nozzle in Noz stocker.
490709
Nozzle set up
Nozzle exchange abnormal data was found.
Please confirm the nozzle arrangement and the Stocker arrangement data.
49070a
Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set up
Placement Hd / Noz data is not corresponding to the real arrangement.
Please confirm the real arrangement of the head nozzle arrangement data and the
head.
49070c
Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and confi
rm there is no unexpected value.
49070d Nozzle set up
The nozzle receipt check went wrong.
Please select a recognition image and choose the existence of a nozzle.
0606-009
3.7 Automatic Setup
3-27
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Please confirm the nozzle has not adhered to the position. Moreover, please clean
the line sensor when not adhering.
49070f Nozzle set up
The placed nozzle was undetectable on the head.
Please confirm whether the nozzle has adhered to the position.
490710
Nozzle set up
The receipt nozzle was undetectable on the head.
Please confirm whether the nozzle has adhered to the position.
490711
Nozzle set up
The remains nozzle was detected on the head.
Please confirm the nozzle has not adhered to the position. Moreover
, please clean
the line sensor when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.
490713
Nozzle set up
The nozzle exchange sequence error occurred.
Please confirm the nozzle arrangement.
490714 Nozzle set up
The nozzle placement in nozzle stocker is dif
ferent from the nozzle data.
Please confirm the nozzle placement.
490715
Nozzle set up
It failed in nozzle ID detection.
Please confirm the nozzle ID.
490716
Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle st
ocker was
opened for safety. Please confirm whether there is no rise to the
surface and the nozzle is not in opening and shutting caught state.
0606-009
3.7 Automatic Setup
3-28
AIVEMT-ID
3.8 Head-Related Errors
Table 4C10
Erroe ID Error Name, Description, Cause, and Remedy
4A0101 Head Zero Return
NL axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
Please check error on a “MAINT-DVC CHK- MOTOR” screen.
4A0102
Head Zero Return
HL axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
Please check error on a “MAINT-DVC CHK- MOTOR” screen.
4A0103
Head Zero Return
L1 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
Please check error on a “MAINT-DVC CHK- MOTOR” screen.
4A0104 Head Zero Return
L2 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
Please check error on a “MAINT
-DVC CHK- MOTOR” screen.
4A0105 Head Zero Return
L3 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
Please check error on a “MAINT
-DVC CHK- MOTOR” screen.
0606-009
3.8 Head-Related Errors