4OM-1208-011_w.pdf - 第171页
3-20-1 AIVEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 425301 Output Cnvr . Error The carrying in operation was not able to begin. ----- 425302 Output Cnvr . Error The error was detected while carrying in …

3-20
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
425201 Output Cnvr. PCB Detection
PCB’s were at inlet and outlet of cnvr.
Please continue the work after checking the PCB on a conveyor.
425202
Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB fell while moving to the receiving position.
Please continue production after checking whether the PCB has fallen around a
conveyor.
425203
Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB was removed.
-----
425204 Output Cnvr. PCB Detection
There is no PCB on the Cnvr. The PCB could not be discharged.
Please continue the work after checking the PCB on a conveyor.
425205 Output Cnvr. PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
Please continue the work after checking the PCB on a conveyor.
425206
Output Cnvr. PCB Detection
The PCB was detected by the conveyer entrance sensor.
Please continue the work after checking the PCB on a conveyor.
425207 Output Cnvr
. PCB Detection
The PCB was detected with the conveyer exit sensor.
Please confirm the PCB on the conveyer.
425210
Output Cnvr. PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the PCB carried out manual bypass. Production can be continued.
425211 Output Cnvr. PCB Detection
The PCB was not found in the proper position.
Please remove the PCB on a conveyor. Production can be continued.
425212
Output Cnvr. PCB Detection
Manual bypass of the PCB was carried out.
Please remove the PCB carried out manual bypass. Production can be continued.
0606-009
3.3 Conveyor

3-20-1
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
425301 Output Cnvr. Error
The carrying in operation was not able to begin.
-----
425302 Output Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
425303 Output Cnvr. Error
The exhaust operation was not able to begin.
-----
425304 Output Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
425305 Output Cnvr. Error
The PCB transport to receiving position was not able to begin.
-----
425306 Output Cnvr. Error
The error was detected while transporting to the receiving position.
-----
425307 Output Cnvr. Error
The operation moving to the arrangement position was not able to begin.
-----
425308 Output Cnvr. Error
The error was detected while transporting to the arrangement position.
-----
425309 Output Cnvr. Error
The reversal positioning operation was not able to begin.
-----
425310 Output Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
0606-009
3.3 Conveyor

3-21
AIVEMT-ID
0606-009
3.4 Recognition Communication
3.4 Recognition Communication
Table 4C6
Erroe ID Error Name, Description, Cause, and Remedy
450101 Recog. Comm. Error
Recognition Error Code.
-----
450102 Recog. Comm. Error
Time-Out Error
-----
450103 Recog. Comm. Error
GUI starting failure.
-----