4OM-1208-011_w.pdf - 第88页
1-31 AIVEMT -ID 0606-009 3.3 Inspection, Cleaning, and Lubrication Spots 3.3.7 Head Section Linear Measure Sensors (Light Emitter and Receiver) Every Day Cleaning Required T ime: 5 minutes If sebum and oil, etc., adhere …

1-30
AIVEMT-ID
WARNING
Pay close attention to the cutter blade during the maintenance
work.
•
Lack of attention will result in a hand injury, etc.
•
Be sure to attach the fixing jig to the cut unit during the
maintenance work for safety purposes.
Attachment Position of
Cut Unit Fixing Jig
Attachment Position of
Cut Unit Fixing Jig
When the tape guide is
detached or attached,
be sure to keep the Y-axis
linear scale free of nicks
and scratches.
Notice
Flat Ring
Every 3 Months Replacement
Required Time: 10 minutes
(1) Remove four screws and detach the tape guide.
(2) Use the inner holes of the cut unit fixing jig with the
tape clamp being closed and attach the jig with the
bent portion being directed upward.
Fluorine Sheet, Urethane Clamp
Ever Year Replacement
Required Time: 5 minutes
(1) Remove four screws and detach
the tape guide.
(2) Use the outer hole of the cut unit
f
ixing jig and attach the jig with the
bent portion being directed downward.
(3) Replace the fluorine sheet and the
urethane clamp.
Refer to "4.3 Replacement of
Fluorine Sheet and Urethane
Clamp" for the replacement
procedure.
Note
After the fluorine sheet has been
replaced, activate the cutter
without a tape and cut the
fluorine sheet.
Reference
Tape Guide
(3) Cut the used flat ring with a cutter on market and
detach it.
(4) Attach a new flat ring to the flat ring replacement jig.
(5) Put the flat ring replacement jig on the roller on the
oscillating side (outside of the machine) and push
down the flat ring until it is inserted into the groove
of the roller.
Replacement Jig
Attached
Fig. 4A19-3
0606-009
3.3 Inspection, Cleaning, and Lubrication Spots

1-31
AIVEMT-ID
0606-009
3.3 Inspection, Cleaning, and Lubrication Spots
3.3.7 Head Section
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
If sebum and oil, etc., adhere to the surface
of the linear measure sensor, wipe them
off with a cotton swab soaked in absolute
ethanol. After that, blow air to the surface
to remove dirt and dust.
Nozzle U/D Linear Guides (2 places)
Every Month Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off the old grease with a rag and
apply a small amount of new grease
with a syringe.
(2) Turn the coupling by hand and move
the nozzle U/D linear guides up and
down to smooth out the grease.
(3) Wipe off excess grease.
Take ample care not to leave
any waste threads after
cleaning.
Use No. 18 (green) nozzle.
Coupling
No.18
Notice
Note
Notice
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
(1) Store all nozzles in the nozzle stocker
(housing) through window navigations.
(2) Wipe the diffusion p late with a dry
lens cleaning cloth.
Sebum or oil should not
adhere to the surface of the
diffusion plate.
Refer to "6. "Nozzle Change"
Window" in "Chapter 3 (Vol. 2)"
for the procedure of nozzle storage.
Nozzle U/D Ball Screw
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required T
ime: 5 minutes
Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Reference
Fig. 4A20

1-32
AIVEMT-ID
Nozzle Change Cam Face (Lower Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 2 minutes
If a foreign substance adheres to the
nozzle change cam face, remove them with
a pair of tweezers.
Apply grease (0.01 cc) to the cam face with
a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
No. 19
Fig. 4A21
0606-009
3.3 Inspection, Cleaning, and Lubrication Spots