4OM-1208-011_w.pdf - 第166页

3-16 AIVEMT -ID Erroe ID Error Name, Description, Cause, and Remedy 423101 Input Cnvr . PCB Overtime The PCB transport (carry in) from Cnvr . Positioning1 did not end in prescribed time. ----- 423102 Input Cnvr . PCB Ove…

100%1 / 237
3-15
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
422301 Cnvr. Positioning 1 Error
The carrying in operation was not able to begin.
-----
422302 Cnvr. Positioning 1 Error
The error was detected while carrying in was operating.
Please continue the work after checking the PCB on a conveyor.
422303 Cnvr. Positioning 1 Error
The exhaust operation was not able to begin.
-----
422304 Cnvr. Positioning 1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the PCB on a conveyor.
422305 Cnvr. Positioning 1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning 1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning 1 Error
Rise operation of a PCB locate stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning 1 Error
Downward operation of a PCB locate stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning 1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning 1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the PCB on a conveyor.
422311 Cnvr. Positioning 1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning 1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the PCB on a conveyor.
0606-009
3.3 Conveyor
3-16
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
423101 Input Cnvr. PCB Overtime
The PCB transport (carry in) from Cnvr. Positioning1 did not end in prescribed time.
-----
423102 Input Cnvr. PCB Overtime
The PCB transport (exhaust) to Cnvr. Positioning1 did not end in prescribed time.
-----
423103 Input Cnvr. PCB Overtime
The reversal positioning operation did not end in prescribed time.
-----
423201 Input Cnvr. PCB Detection
PCB’s were at inlet and outlet of cnvr.
-----
423202 Input Cnvr. PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
-----
423203 Input Cnvr. PCB Detection
The conveyer entrance sensor detected PCB
-----
423301 Input Cnvr. Error
The carrying in operation was not able to begin.
-----
423302 Input Cnvr. Error
The error was detected while carrying in was operating.
-----
423303 Input Cnvr. Error
The exhaust operation was not able to begin.
-----
423304 Input Cnvr. Error
The error was detected while exhaust was operating.
-----
423305 Input Cnvr. Error
The reversal positioning operation was not able to begin.
-----
423306 Input Cnvr. Error
The error was detected while the reversal positioning was operating.
-----
0606-009
3.3 Conveyor
3-17
AIVEMT-ID
Erroe ID Error Name, Description, Cause, and Remedy
424101 Cnvr. Positoining 2 Overtime
The PCB transport (carry in) from input cnvr. did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424102 Cnvr
. Positoining 2 Overtime
The PCB transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424103 Cnvr
. Positoining 2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr. Positoining 2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr. Positoining 2 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424107 Cnvr. Positoining 2 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the PCB on a conveyor.
424201 Cnvr. Positioning 2 PCB Detection
PCB’s were at inlet and outlet of cnvr
.
Please continue the work after checking the PCB on a conveyor.
424202
Cnvr. Positioning 2 PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able to
be detected.
Please continue the work after checking the PCB on a conveyor.
424203
Cnvr. Positioning 2 PCB Detection
No PCB on the cnvr. After positioning released, PCB could not be detected.
Please continue the work after checking the PCB on a conveyor.
424204
Cnvr. Positioning 2 PCB Detection
The conveyer entrance sensor detected PCB
Please continue the work after checking the PCB on a conveyor.
0606-009
3.3 Conveyor