MAN00000772_SI-G200BB_SVCPDFA.pdf - 第143页
O pe r a ti on Guide W o rk Pr ocess Parts R e placem ent Maintenan ce I ntended i tem S I -G200 A A BB Docume n t no. W KGB- 2 0105-0 1 Page 1/8 SI - G200 AA BB SH ter m inal s se p ara t ion t o prev e nt gr ound rela …

System software clear installation process
WKGB-10109-01
8. ASM Software Setup screen appears. Keep it until installation is completed.
9. Information screen appears. Click OK button.
10. The installation is completed.
System software clear installation process
11/11

Operation Guide Work Process Parts Replacement Maintenance
Intended item SI-G200 AA BB
Document no. WKGB-20105-01
Page 1/8
SI-G200 AA BB SH terminals separation to prevent ground relay
Take off SH terminal from machine frame and covers to insulate with plastic tape. After insulation fix
SH lines to prevent interfering during production.
CONTENTS
[Required equipments]...............................................................................................................................2
1. Before work...........................................................................................................................................2
2. Taking off SH terminals of feed cover ................................................................................................ 4
3. Taking off SH terminals of X-Y relay .................................................................................................5
4. Taking off SH terminals of upper frame ............................................................................................7
5. Return back original condition............................................................................................................8
Before After

Operation Guide Work Process Parts Replacement Maintenance
Intended item SI-G200 AA BB
Document no. WKGB-20105-01
Page 2/8
[Required equipments]
Hexagon wrench
Nipper
Nylon tie (AB 150, AB 100)
Screw driver (Plus)
Screw driver plus, with short length (See photo.)
Plastic tape
Screw driver plus, with short length
1. Before work
Power off machine.
Loosen 2 CP 4 x 45 from machine inside shown as photo, to take
off top plate which is on machine both sides.
Power off switch
Main breaker