Set-up
HLGB-10203-01
Acquiring Mounting Stroke Setup
SHEET
3/5
6 Enter thickness (0.03 mm) of thickness
gauge used for placement height adjustment
in a space box on the Acquiring mounting
stroke screen.
7 Move the head unit onto the calibration plate
jig.
1. Click the XY button on the Acquiring
mounting stroke screen.
XY Axis screen is displayed.
2. Click the Jog Move button.
3. Press the cursor key to jog move the
head unit onto the calibration plate
jig.
4. Click the Return button to return to
the Acquiring mounting stroke screen.
8 Adjust gap between the length reference
nozzle jig and calibration plate jig.
1. Click the R.H button on the Acquiring
mounting stroke screen.
RN/H Axis screen is displayed.
2. Click the Jog Move button.
3. Press the downward cursor key and
lower until the gap between the length
reference nozzle jig and calibration
plate jig becomes 0.03mm.
Slowly lower by Jog slow move while checking
the nozzle position so that the length reference
nozzle jig does not collide he calibration plate
jig.

Set-up
HLGB-10203-01
Acquiring Mounting Stroke Setup
SHEET
4/5
4. Check the gap between the length
reference nozzle jig and calibration
plate jig using thickness gauge of
0.03mm.
Set a height so hat thickness gauge of 0.03mm is
inserted and thickness gauge of 0.04mm is not
inserted.
5. After completing to adjust the gap of
0.03mm, press the Return button on
the RN/H Axis screen to return to the
Acquiring mounting stroke screen.
6. Click the Save button on the Acquiring
mounting stroke screen.
Height of adjusted H axis is saved, and value of
“Nozzle_s_TYPE_G” in the calib.ini file is
updated.
< Storing area of calib.ini file >
Front side: C:¥asm¥mcdata1¥calib.ini
Rear side: C:¥asm¥mcdata2¥calib.ini
9 Set the PWB fitting height.
1. Record the value of
NOZZLE_S_TYPE_G described in
calib.ini.
< Storing area of calib.ini file >
Front side: C:¥asm¥mcdata1¥calib.ini
Rear side: C:¥asm¥mcdata2¥calib.ini
2. Click in an order of M/C SETUP menu
MOTION SETUP tab Nozzle tab.
A nozzle motion setup screen is displayed.
Length reference nozzle jig
Thickness gauge

Set-up
HLGB-10203-01
Acquiring Mounting Stroke Setup
SHEET
5/5
3. Input a value of 1/1000 of the value
described in calib.ini into the Mount
height.
Example:
Description of Calib.ini:
NOZZLE_S_TYPE_G=-23162
PWB mount height input value :-23.162
4. Press the Set button.
The inputted PWB fitted height is set.
10 When setting is ended, remove the
reference jig nozzle and calibration plate.