Calibration HLGB-10305-01 Auto Calibration (Recognition of Relationship be t ween the Fi xed Camera and Nozzle) SHEET 1/4 Auto Calibration (Recognition of Relationship between the Fixed Camera and Nozzle) [Necessary jigs…

Calibration
HLGB-10304-01
Auto Calibration (Recognition of
relationship between PWB coordinate and
mechanism coordinate)
SHEET
7/7
11 Check that it was normally ended, and click
the Save button.
Calibration result is saved.
12 Remove the ball point jig, and then reattach
the rail stopper, PWB presser rails, and
nozzle cartridges to their original location.
13 Go on to the procedure of recognition of relationship between the fixed camera and nozzle, and
then to the procedure of Recognition of relationship for the Multiple Recognition.
・ For the recognition of relationship between the fixed camera and nozzle procedure, refer to “Auto Calibration
(Recognition of Relationship between the Fixed Camera and Nozzle)[HLGB-10305-01]”.
・ For the recognition of relationship for the Multiple Recognition procedure, refer to “Auto Calibration (Recognition of
relationship for the Multiple Recognition)[HLGB-10306-01]”.

Calibration
HLGB-10305-01
Auto Calibration (Recognition of
Relationship between the Fixed Camera
and Nozzle)
SHEET
1/4
Auto Calibration (Recognition of Relationship between the Fixed
Camera and Nozzle)
[Necessary jigs]
A Calibration data FD
B Calibration plate jig
C Positioning pins for calibration plate
D BF00900 nozzle (1 pc.)
E BF60400 nozzle (7 pcs.)
F Calibration jig chip (t=3.4, 1 pc.)
G Calibration jig chip (t=1.4, 8 pcs.)
H Calibration jig chip (glass)
[Procedure]
1 Load the calibration data.
For calibration data loading procedure, refer to “Calibration Data Load [HLGB-10105-01]”.
2 Install the calibration plate jig.
For mounting method of the calibration plate jig, refer to “Install the Calibration Plate Jig [HLGB-10101-01]”.
3 Put the jig tip on the calibration plate.
1. Put 8 thinner jig chips (t=1.4mm) to
front side.
2. Put thicker jig chip (t=3.4mm) to the
right end of the deep row.
3. Put jig chip (glass) on the right
countersunk section.
Set the jig chips so that surface on which glass
black point (pattern) is printed is directed
upward.
E
D
A
B
C
F
G H
Jig chip (t=3.4mm)
Jig chip (t=1.4mm) Jig chip (glass)

Calibration
HLGB-10305-01
Auto Calibration (Recognition of
Relationship between the Fixed Camera
and Nozzle)
SHEET
2/4
4 Move the head clear of the work area.
1. Click in an order of MANUAL menu
AXIS MOTION tab XY button.
XY Axis screen is displayed.
2. Click the Jog Move button in the move
mode.
3. Press the cursor key to move the head
to a position where working is easily
performed.
4. After moving the head, click the Return
button to close the XY axis screen.
5 Install the jig nozzles to head.
1. Install the BF00900 nozzles (1 piece)
to the turrets No.1.
2. Install the BF60400 nozzles (7 pieces)
to the turrets No.2~8.
Attach the nozzle so that the mark of the nozzle
type comes outer side of the turret.
Do not execute the automatic replacement of
the nozzle using the nozzle changer when the
calibration has not been completed.
6 Display a Recognition of relationship
between AUX camera and nozzle screen.
1. Click the Auto Calibration button on
the CALIBRATION screen.
Multi-functional machine calibration screen is
displayed.
BF60400 nozzle
BF00900 nozzle