Adjustment HLGB-10419-01 Fixed Camera Pickup Ch eck Sensor Adj ust ment SHEET 1/7 Fixed Camera Pickup Check Sensor Adjustment Perform this operat ion for fixed camer a pickup check sensors on both of fro nt and rear side…

Adjustment
HLGB-10418-01
Adjustment of PWB Stopper Sensor
SHEET
2/2
4 Adjust sensitivity of the PWB stopper
sensor.
1. Make adjustment by turning the
sensitivity adjustment volume of the
sensor amplifier so that the PWB
stopper sensor is turned on (both of the
green LED and orange LED light up)
at this position.
5 Check that the up end of the PWB stopper is
as high as the conveyor rail.
6 Remove the PWB.
1. Click the Stopper Down button to
lower the reference pin.
2. Remove the PWB on the conveyor.
Conveyor rail
PWB stopper

Adjustment
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
SHEET
1/7
Fixed Camera Pickup Check Sensor Adjustment
Perform this operation for fixed camera pickup check sensors on both of front and rear sides.
[Necessary jigs]
A Fixed camera Jig base (G200)
B Nozzle Jig for fixed camera
C Fixed camera parts presence/absence
sensor adjustment Jig
D Sensor adjusting nozzle (1)/long thin
E Sensor adjusting nozzle (2)/short thick
[Procedure]
1 Remove the lower cover and shooter on the
front and rear of the unit.
1. Loosen screw (2-+T4x8) to remove the
lower cover.
Tile the lower cover slightly toward you and pull
the fan cable to remove the lower panel.
2. Loosen screw (2-+T4x8) to remove the
shooter.
2 Loosen cap screws (2-CP5x10) fixing the
fixed camera cooling fan to remove the fan.
Temporarily place the removed fan on the side of the
fixed camera.
B
A
C
D E
Lower cover
Shooter
Cap screw
Cooling fan

Adjustment
HLGB-10419-01
Fixed Camera Pickup Check Sensor
Adjustment
SHEET
2/7
3 Fix the fixed camera jig base with cap
screws (2-CP5x20).
Carry out working with care not to damage the
fiber cable for parts presence/absence detecting
sensor.
4 Check setup of the sensor amplifier.
1. Open the cover for the sensor
amplifier.
2. Turn the SET/RUN selector switch to
SET.
3. Press the MODE button to select item
to be set.
4. Press the UP/DOWN button to change
the set button.
SET RUN
L D
Item to be set Indication Set value
Detecting function setup (Standard function)
1-Fn Stnd
Timer function (Not used)
2-bF ----
MODE setup(Power tuning execution)
3-Ad PtUn
Power tuning target value setup
PL 2000
Indication switching(light receiving quantity,
threshold are indicated)
2134 1000
Indicating direction setup
5-ru d123
Fixed camera jig base
Fiber cable
Cap screw
SET/RUN selector switch
Operation mode selector switch
MODE button
UP/DOWN button
Sensor amplifier